Worked example
24-Inch Pond Waterfall Flow at 150 GPH per Inch
This smaller pond has a broad 24 in waterfall. At 150 GPH per inch, its waterfall target is higher than the pond’s single-turnover circulation target.
See the worked calculationInputs
Results
Edit inputs24-Inch Pond Waterfall Flow at 150 GPH per Inch
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/24-inch-pond-waterfall-150-gph-per-inch/
- Waterfall flow alone
- 3,600 US gal/h
- Estimated pond volume
- 1,496 US gal
- Single-loop pump flow at head
- 3,600 US gal/h
Calculation details
- Planning UV clarifier capacity
- 20.4 W
- Minimum sheet length
- 19 ft
- Minimum sheet width
- 17 ft
- Circulation flow alone
- 1,496 US gal/h
- Estimated total dynamic head
- 5 ft
- Check the finished excavation with a rope or tape before ordering a liner.
- Match the pump curve at total head and the UV model’s koi volume and flow ratings.
Input measurements
- Pond plan
- Rectangular
- Maximum length
- 10 ft
- Maximum width
- 8 ft
- Average water depth
- 2.5 ft
- Maximum liner depth
- 3 ft
- Extra liner per edge
- 1.5 ft
- Spillway width
- 24 in
- Flow per unit of spillway width
- 150 US gal/h/in
- Circulation target per hour
- 1 ×
- Static lift to discharge
- 3 ft
- Friction head allowance
- 2 ft
- Planning UV power density
- 13.62748 W/1,000 US gal
Meter the actual fill and test pH, ammonia, nitrite and dissolved oxygen before stocking. Check the pump and UV ratings for your stock load and install electrical equipment according to its manual.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Estimate pond volume from the water plan
10 ft × 8 ft × 1 × 2.5 ft → 1,496 US gal
The shape factor applies to the water footprint. Use area-weighted water depth and convert the resulting cubic volume to gallons or liters.
Add liner depth and overlap to each direction
2 × (3 ft + 1.5 ft) per dimension → 19 ft × 17 ft
Use maximum depth and the full bounding dimensions for the sheet.
Compare waterfall and turnover demand
24 in × 150 US gal/h/in = 3,600 US gal/h; circulation = 1,496 US gal × 1/h → 1,496 US gal/h
Use the larger flow on a single loop. Select at 5 ft total head.
Estimate UV clarifier watts
5.663 kL × 3.6 W/kL = 20.39 W
Compare actual koi volume and allowable flow against a manufacturer chart.
Frequently asked questions
What if I want a gentler sheet across the 24-inch waterfall?
Enter the lower per-inch flow specified by the spillway manufacturer, then compare the resulting waterfall requirement with circulation.
Why can a 24-inch weir look uneven at the calculated flow?
Level, lip geometry, debris and approach flow matter. Set the weir level and verify the operating pattern after installation.