Worked example
12 × 8 ft Oval Koi Pond Volume and Liner
The pond is oval, 12 ft by 8 ft at the water line, with a 2.5 ft average depth and 3 ft maximum depth. Use an ellipse for volume and the full bounding dimensions for the liner.
See the worked calculationInputs
Results
Edit inputs12 × 8 ft Oval Koi Pond Volume and Liner
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/12x8-foot-oval-koi-pond-volume-liner/
- Estimated pond volume
- 1,410 US gal
- Single-loop pump flow at head
- 2,700 US gal/h
- Planning UV clarifier capacity
- 19.2 W
Calculation details
- Minimum sheet length
- 21 ft
- Minimum sheet width
- 17 ft
- Waterfall flow alone
- 2,700 US gal/h
- Circulation flow alone
- 1,410 US gal/h
- Estimated total dynamic head
- 6 ft
- Check the finished excavation with a rope or tape before ordering a liner.
- Match the pump curve at total head and the UV model’s koi volume and flow ratings.
Input measurements
- Pond plan
- Oval or round
- Maximum length
- 12 ft
- Maximum width
- 8 ft
- Average water depth
- 2.5 ft
- Maximum liner depth
- 3 ft
- Extra liner per edge
- 1.5 ft
- Spillway width
- 18 in
- Flow per unit of spillway width
- 150 US gal/h/in
- Circulation target per hour
- 1 ×
- Static lift to discharge
- 4 ft
- Friction head allowance
- 2 ft
- Planning UV power density
- 13.62748 W/1,000 US gal
Meter the actual fill and test pH, ammonia, nitrite and dissolved oxygen before stocking. Check the pump and UV ratings for your stock load and install electrical equipment according to its manual.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Estimate pond volume from the water plan
12 ft × 8 ft × 0.7854 × 2.5 ft → 1,410 US gal
The shape factor applies to the water footprint. Use area-weighted water depth and convert the resulting cubic volume to gallons or liters.
Add liner depth and overlap to each direction
2 × (3 ft + 1.5 ft) per dimension → 21 ft × 17 ft
Use maximum depth and the full bounding dimensions for the sheet.
Compare waterfall and turnover demand
18 in × 150 US gal/h/in = 2,700 US gal/h; circulation = 1,410 US gal × 1/h → 1,410 US gal/h
Use the larger flow on a single loop. Select at 6 ft total head.
Estimate UV clarifier watts
5.338 kL × 3.6 W/kL = 19.22 W
Compare actual koi volume and allowable flow against a manufacturer chart.
Frequently asked questions
How much volume does the oval shape remove from a 12 × 8 rectangle?
The ellipse uses π/4 of the bounding rectangle, about 78.5% of its plan area. That assumes a regular oval and the same average depth.
Why does the oval sheet calculation keep the full length and width?
A flat sheet has to reach both ends and fold down into the deepest contours. Round corners do not shorten those maximum spans.