Worked example

Irregular Koi Pond with Shelves: Volume and EPDM Overlap

An irregular 16 × 11 ft footprint occupies 72% of its bounding rectangle. Use 2.1 ft of average depth for water and 4 ft of maximum depth plus 2 ft per edge for the liner.

See the worked calculation

Inputs

View results
Pond and liner
ft
ft
%

Share of the bounding rectangle occupied by water.

ft

Use an area-weighted average where there are shallow shelves.

ft

Measure from the liner crest to the deepest point.

ft

Use enough material for your edge, anchoring and folds.

Waterfall and circulation
in

Enter 0 if there is no waterfall.

US gal/h/in

Use the spillway’s rated flow for the sheet thickness you want.

×
ft
ft

Include pipe, valves and filter loss at the target flow.

UV clarifier
W/1,000 US gal

Match koi capacity and allowable flow on a manufacturer’s chart.

Minimum sheet width
23 ft
Estimated pond volume
1,991 US gal
Single-loop pump flow at head
2,700 US gal/h
Pond profile, EPDM sheet and overlapEstimated pond volume 1,991 US gal. Minimum sheet 28 ft by 23 ft. EPDM liner follows the excavation Max liner depth4 ftPer-edge overlap2 ftWater volume1,991 US galMinimum sheet28 ft × 23 ft
Pond section & liner allowance

Calculation details

Planning UV clarifier capacity
27.1 W
Minimum sheet length
28 ft
Waterfall flow alone
2,700 US gal/h
Circulation flow alone
1,991 US gal/h
Estimated total dynamic head
6 ft
  • Check the finished excavation with a rope or tape before ordering a liner.
  • Match the pump curve at total head and the UV model’s koi volume and flow ratings.

Input measurements

Pond plan
Irregular bounding rectangle
Maximum length
16 ft
Maximum width
11 ft
Water plan coverage
72 %
Average water depth
2.1 ft
Maximum liner depth
4 ft
Extra liner per edge
2 ft
Spillway width
18 in
Flow per unit of spillway width
150 US gal/h/in
Circulation target per hour
1 ×
Static lift to discharge
4 ft
Friction head allowance
2 ft
Planning UV power density
13.62748 W/1,000 US gal

Meter the actual fill and test pH, ammonia, nitrite and dissolved oxygen before stocking. Check the pump and UV ratings for your stock load and install electrical equipment according to its manual.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Estimate pond volume from the water plan

    16 ft × 11 ft × 0.72 × 2.1 ft → 1,991 US gal

    The shape factor applies to the water footprint. Use area-weighted water depth and convert the resulting cubic volume to gallons or liters.

  2. Add liner depth and overlap to each direction

    2 × (4 ft + 2 ft) per dimension → 28 ft × 23 ft

    Use maximum depth and the full bounding dimensions for the sheet.

  3. Compare waterfall and turnover demand

    18 in × 150 US gal/h/in = 2,700 US gal/h; circulation = 1,991 US gal × 1/h → 1,991 US gal/h

    Use the larger flow on a single loop. Select at 6 ft total head.

  4. Estimate UV clarifier watts

    7.535 kL × 3.6 W/kL = 27.13 W

    Compare actual koi volume and allowable flow against a manufacturer chart.

Frequently asked questions

How can I estimate 72% coverage for an irregular pond?

Overlay a square grid on a plan or aerial photo. Divide the filled square area by the bounding rectangle and include partial squares along the edge.

What depth should I assign to a broad shallow plant shelf?

Use its actual depth in an area-weighted average. Keep the deepest point as the maximum for liner sizing.