Worked example
2,500-Gallon Koi Pond UV Clarifier Watts
The rectangular pond measures 15 × 12 ft with a 1.85 ft average depth. Start at 3.6 W per 1,000 L as a provisional clarifier sizing density.
See the worked calculationInputs
Results
Edit inputs2,500-Gallon Koi Pond UV Clarifier Watts
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/2500-gallon-koi-pond-uv-clarifier-watts/
- Planning UV clarifier capacity
- 33.9 W
- Estimated pond volume
- 2,491 US gal
- Single-loop pump flow at head
- 2,700 US gal/h
Calculation details
- Minimum sheet length
- 24 ft
- Minimum sheet width
- 21 ft
- Waterfall flow alone
- 2,700 US gal/h
- Circulation flow alone
- 2,491 US gal/h
- Estimated total dynamic head
- 6 ft
- Check the finished excavation with a rope or tape before ordering a liner.
- Match the pump curve at total head and the UV model’s koi volume and flow ratings.
Input measurements
- Pond plan
- Rectangular
- Maximum length
- 15 ft
- Maximum width
- 12 ft
- Average water depth
- 1.85 ft
- Maximum liner depth
- 3 ft
- Extra liner per edge
- 1.5 ft
- Spillway width
- 18 in
- Flow per unit of spillway width
- 150 US gal/h/in
- Circulation target per hour
- 1 ×
- Static lift to discharge
- 4 ft
- Friction head allowance
- 2 ft
- Planning UV power density
- 13.62748 W/1,000 US gal
Meter the actual fill and test pH, ammonia, nitrite and dissolved oxygen before stocking. Check the pump and UV ratings for your stock load and install electrical equipment according to its manual.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Estimate pond volume from the water plan
15 ft × 12 ft × 1 × 1.85 ft → 2,491 US gal
The shape factor applies to the water footprint. Use area-weighted water depth and convert the resulting cubic volume to gallons or liters.
Add liner depth and overlap to each direction
2 × (3 ft + 1.5 ft) per dimension → 24 ft × 21 ft
Use maximum depth and the full bounding dimensions for the sheet.
Compare waterfall and turnover demand
18 in × 150 US gal/h/in = 2,700 US gal/h; circulation = 2,491 US gal × 1/h → 2,491 US gal/h
Use the larger flow on a single loop. Select at 6 ft total head.
Estimate UV clarifier watts
9.43 kL × 3.6 W/kL = 33.95 W
Compare actual koi volume and allowable flow against a manufacturer chart.
Frequently asked questions
Does a roughly 34 W estimate mean any 36 W UV suits a 2,500-gallon koi pond?
No. Use the UV unit’s koi volume limit, maximum flow, bypass and lamp condition to check the exact model.
Will a UV clarifier make a koi pond safe to stock sooner?
Clarification addresses suspended algae. Confirm biofilter readiness and measure ammonia, nitrite, pH and oxygen before stocking.