Pond engineering

Koi Pond Volume, Liner, Pump & UV Sizing Calculator

Size koi pond gallons, EPDM liner, waterfall weir flow, circulation pump at head and preliminary UV clarifier wattage.

Inputs

View results
Pond and liner
ft
ft
ft

Use an area-weighted average where there are shallow shelves.

ft

Measure from the liner crest to the deepest point.

ft

Use enough material for your edge, anchoring and folds.

Waterfall and circulation
in

Enter 0 if there is no waterfall.

US gal/h/in

Use the spillway’s rated flow for the sheet thickness you want.

×
ft
ft

Include pipe, valves and filter loss at the target flow.

UV clarifier
W/1,000 US gal

Match koi capacity and allowable flow on a manufacturer’s chart.

Estimated pond volume
3,366 US gal
Single-loop pump flow at head
3,366 US gal/h
Planning UV clarifier capacity
45.9 W
Pond profile, EPDM sheet and overlapEstimated pond volume 3,366 US gal. Minimum sheet 24 ft by 19 ft. EPDM liner follows the excavation Max liner depth3 ftPer-edge overlap1.5 ftWater volume3,366 US galMinimum sheet24 ft × 19 ft
Pond section & liner allowance

Calculation details

Minimum sheet length
24 ft
Minimum sheet width
19 ft
Waterfall flow alone
2,700 US gal/h
Circulation flow alone
3,366 US gal/h
Estimated total dynamic head
6 ft
  • Check the finished excavation with a rope or tape before ordering a liner.
  • Match the pump curve at total head and the UV model’s koi volume and flow ratings.

Input measurements

Pond plan
Rectangular
Maximum length
15 ft
Maximum width
10 ft
Average water depth
3 ft
Maximum liner depth
3 ft
Extra liner per edge
1.5 ft
Spillway width
18 in
Flow per unit of spillway width
150 US gal/h/in
Circulation target per hour
1 ×
Static lift to discharge
4 ft
Friction head allowance
2 ft
Planning UV power density
13.62748 W/1,000 US gal

Meter the actual fill and test pH, ammonia, nitrite and dissolved oxygen before stocking. Check the pump and UV ratings for your stock load and install electrical equipment according to its manual.

How the calculation works

Volume is plan area times average water depth. A rectangular plan uses the full bounding rectangle, an oval uses π/4 of it, and an irregular plan uses the coverage you enter. Recheck the estimate with a metered fill.

Size the liner from maximum dimensions. To both length and width add two maximum depths and two edge overlaps. For contours, verify the route with a tape or rope laid into the finished excavation and round up to a stocked fish-safe EPDM size.

A return routed entirely over the waterfall uses the larger of waterfall flow and turnover flow. Select a pump that delivers that rate at the estimated total head. Separate circuits have independent flow requirements. UV watts are a preliminary estimate for clarity. Check the manufacturer’s koi volume, contact time and rated flow.

References

Frequently asked questions

Which pond depth should I use for liner and for volume?

Use maximum liner depth for sheet size and area-weighted average water depth for volume. A wide plant shelf makes the average depth shallower than the deepest pocket.

Why must a pond UV clarifier be sized by flow as well as watts?

Flow affects the time algae spend in the UV chamber. Use the maker’s koi or pond volume rating and the allowable flow through the model in your planned circuit.