Pond engineering
Koi Pond Volume, Liner, Pump & UV Sizing Calculator
Size koi pond gallons, EPDM liner, waterfall weir flow, circulation pump at head and preliminary UV clarifier wattage.
Inputs
Results
Edit inputsKoi Pond Volume, Liner, Pump & UV Sizing Calculator
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/koi-pond-volume-liner-pump-uv-sizing-calculator/
- Estimated pond volume
- 3,366 US gal
- Single-loop pump flow at head
- 3,366 US gal/h
- Planning UV clarifier capacity
- 45.9 W
Calculation details
- Minimum sheet length
- 24 ft
- Minimum sheet width
- 19 ft
- Waterfall flow alone
- 2,700 US gal/h
- Circulation flow alone
- 3,366 US gal/h
- Estimated total dynamic head
- 6 ft
- Check the finished excavation with a rope or tape before ordering a liner.
- Match the pump curve at total head and the UV model’s koi volume and flow ratings.
Input measurements
- Pond plan
- Rectangular
- Maximum length
- 15 ft
- Maximum width
- 10 ft
- Average water depth
- 3 ft
- Maximum liner depth
- 3 ft
- Extra liner per edge
- 1.5 ft
- Spillway width
- 18 in
- Flow per unit of spillway width
- 150 US gal/h/in
- Circulation target per hour
- 1 ×
- Static lift to discharge
- 4 ft
- Friction head allowance
- 2 ft
- Planning UV power density
- 13.62748 W/1,000 US gal
Meter the actual fill and test pH, ammonia, nitrite and dissolved oxygen before stocking. Check the pump and UV ratings for your stock load and install electrical equipment according to its manual.
How the calculation works
Volume is plan area times average water depth. A rectangular plan uses the full bounding rectangle, an oval uses π/4 of it, and an irregular plan uses the coverage you enter. Recheck the estimate with a metered fill.
Size the liner from maximum dimensions. To both length and width add two maximum depths and two edge overlaps. For contours, verify the route with a tape or rope laid into the finished excavation and round up to a stocked fish-safe EPDM size.
A return routed entirely over the waterfall uses the larger of waterfall flow and turnover flow. Select a pump that delivers that rate at the estimated total head. Separate circuits have independent flow requirements. UV watts are a preliminary estimate for clarity. Check the manufacturer’s koi volume, contact time and rated flow.
References
Frequently asked questions
Which pond depth should I use for liner and for volume?
Use maximum liner depth for sheet size and area-weighted average water depth for volume. A wide plant shelf makes the average depth shallower than the deepest pocket.
Why must a pond UV clarifier be sized by flow as well as watts?
Flow affects the time algae spend in the UV chamber. Use the maker’s koi or pond volume rating and the allowable flow through the model in your planned circuit.