Isolated external corrosion on X52 pipe
An X52 line has a 3.2 mm deep axial patch across 255 mm of a 9.525 mm wall. Operating MAOP is 6,500 kPa.
Inputs
SI unitsEnter sound wall thickness and an isolated axial metal-loss dimension. Use a design factor equal to the inverse of the required safety factor.
- Burst pressure
- 12,279.16 kPa
- Safe pressure
- 8,840.99 kPa
- ERF
- 0.735
- Wall loss
- 33.6 %
Axial metal-loss profile
SchematicThe entered MAOP fits the selected pressure screen. Verify the defect profile, interactions, safety factor and jurisdiction before disposition.
Calculation details
- Length parameter z
- 13.439
- Original Folias M
- 3.428
- Modified Folias M
- 2.97
- Selected pressure result
- Original B31G
- Original flow stress
- 394.38 MPa
- Modified flow stress
- 427.47 MPa
- Original predicted failure
- 12,279.16 kPa
- Modified predicted failure
- 12,670.76 kPa
- Original safe pressure
- 8,840.99 kPa
- Modified safe pressure
- 9,122.95 kPa
- Intact-wall design cap
- 9,680.24 kPa
- Screened pressure minus MAOP
- 2,340.99 kPa
Inputs used
- Governing method
- Lower of both methods
- Outside diameter
- 508 mm
- Sound wall thickness
- 9.525 mm
- Pipe grade SMYS
- 358.52738 MPa
- Design factor F
- 0.72
- Operating MAOP
- 6,500 kPa
- Metal-loss depth
- 3.2 mm
- Axial defect length
- 255 mm
Worked calculation
Starting values · SI- Depth ratio is 33.5958%. The length parameter z is 13.43853.
- Original and Modified failure estimates are 12,279.15971 and 12,670.75764 kPa, respectively.
- With F = 0.72, the selected safe pressure is 8,840.99499 kPa and ERF is 0.73521.
Compare the two estimates and review the governing ERF against the entered MAOP. Confirm that adjacent defects do not interact.
Method and limits
Calculate the loss and length ratios
Use d/t and z = L²/(D × t). Stop at d/t ≥ 0.80. Use matched dimensions and a verified sound wall thickness.
Evaluate the two profiles
Original B31G uses 1.1 × SMYS. For z ≤ 20, use 2d/(3t) and M = √(1 + 0.8z) in the geometry ratio. For z > 20, use the long-defect ratio (1 − d/t). Modified B31G uses SMYS + 10 ksi and 0.85d/t. M = √(1 + 0.6275z − 0.003375z²) for z ≤ 50, or 0.032z + 3.3 above 50.
Screen the pressure
For each short Original or Modified profile, multiply 2tSflow/D by (1 − area fraction)/(1 − area fraction/M). For long Original use its geometry ratio directly. Screened safe pressure is the lower of F × predicted failure pressure and the intact design pressure 2t × SMYS × F/D. ERF = operating MAOP ÷ screened safe pressure.