Original B31G long-defect branch

A 750 mm patch runs along a 508 mm OD line with a 9.525 mm wall. Maximum depth is 2.8 mm.

Inputs

SI units

Enter sound wall thickness and an isolated axial metal-loss dimension. Use a design factor equal to the inverse of the required safety factor.

mm
mm
MPa
kPa
mm
mm
Burst pressure
10,441.76 kPa
Safe pressure
7,518.07 kPa
ERF
0.865
Wall loss
29.4 %

Axial metal-loss profile

Schematic
Axial metal-loss profile (schematic, not to scale)Outside surfaceAxial sectionPipe boreSound wall datumAXIAL EXTENT750 mmLOSS DEPTH2.8 mmSOUND WALL9.53 mm
Within pressure screen

The entered MAOP fits the selected pressure screen. Verify the defect profile, interactions, safety factor and jurisdiction before disposition.

MAOP ÷ screened safe pressure · limit 1.00

Calculation details

Length parameter z
116.25
Original Folias M
—
Modified Folias M
7.02
Selected pressure result
Original B31G
Original flow stress
394.38 MPa
Modified flow stress
427.47 MPa
Original predicted failure
10,441.76 kPa
Modified predicted failure
12,468.64 kPa
Original safe pressure
7,518.07 kPa
Modified safe pressure
8,977.42 kPa
Intact-wall design cap
9,680.24 kPa
Screened pressure minus MAOP
1,018.07 kPa

Worked calculation

Starting values · SI
  1. Depth ratio is 29.39633%. The length parameter z is 116.25023.
  2. Original and Modified failure estimates are 10,441.75704 and 12,468.64318 kPa, respectively.
  3. With F = 0.72, the selected safe pressure is 7,518.06507 kPa and ERF is 0.86458.

The marked length is above both branch transitions. Original B31G uses the long-defect geometry term with no finite Folias factor shown.

Method and limits

  1. Calculate the loss and length ratios

    Use d/t and z = L²/(D × t). Stop at d/t ≥ 0.80. Use matched dimensions and a verified sound wall thickness.

  2. Evaluate the two profiles

    Original B31G uses 1.1 × SMYS. For z ≤ 20, use 2d/(3t) and M = √(1 + 0.8z) in the geometry ratio. For z > 20, use the long-defect ratio (1 − d/t). Modified B31G uses SMYS + 10 ksi and 0.85d/t. M = √(1 + 0.6275z − 0.003375z²) for z ≤ 50, or 0.032z + 3.3 above 50.

  3. Screen the pressure

    For each short Original or Modified profile, multiply 2tSflow/D by (1 − area fraction)/(1 − area fraction/M). For long Original use its geometry ratio directly. Screened safe pressure is the lower of F × predicted failure pressure and the intact design pressure 2t × SMYS × F/D. ERF = operating MAOP ÷ screened safe pressure.