ASME V Article 4 · AWS D1.1

Circumferential return leg in a large OD pipe

A 304.8 mm OD pipe has a 12.7 mm wall. A 45° inspection records a 26 mm path.

Reading the result. The first bounce is beyond 18.86 mm of sound path. Read the radial indication depth at the measured return time.

Setup

Part geometry

mm
mm
Greater than twice wall thickness.

Sound path

°
35–75° from the surface normal.
mm
m/s
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Flaw depth
8.0533mm
Surface dist.
20.387mm
Half skip
14.573mm
Full skip
29.146mm
Leg 2

Depth is radial from OD. Surface distance follows the OD arc.

Weld section and shear pathPipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.Shear-wave mapUnfolded OD arcActive leg progress37.835%Steel wallShear rayReflector
Pipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.
Active leg / chord
2
One leg or chord sound path
18.863mm
Flat-plate full skip reference
25.4mm
Pulse-echo round-trip time
16.099µs
AWS distance correction
0.047244dB
Max. angle reaching pipe ID
66.444°
OD-only chord arc advance
—
Pipe OD circumference
957.56mm

Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references