ASME V Article 4 · AWS D1.1
Curvature correction on a 200 mm OD pipe
A 45° beam sees a 35 mm sound path in a circumferential scan of a 20 mm wall. Pipe OD is 200 mm.
Reading the result. The pipe-corrected OD surface projection is about 31.74 mm. A flat-plate projection would be about 24.75 mm.
Setup
Part geometry
mm
mm
Greater than twice wall thickness.
Sound path
°
35–75° from the surface normal.
mm
m/s
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Flaw depth
- 19.188mm
- Surface dist.
- 31.736mm
- Half skip
- 29.87mm
- Full skip
- 59.741mm
Leg 2
Depth is radial from OD. Surface distance follows the OD arc.
- Active leg / chord
- 2
- One leg or chord sound path
- 33.294mm
- Flat-plate full skip reference
- 40mm
- Pulse-echo round-trip time
- 21.672µs
- AWS distance correction
- 0.75591dB
- Max. angle reaching pipe ID
- 53.13°
- OD-only chord arc advance
- —
- Pipe OD circumference
- 628.32mm
Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references