ASME V Article 4 · AWS D1.1
OD-only chord in a small thick-wall pipe
A 60° shear beam enters the outside of a 114.3 mm OD pipe with an 18 mm wall.
Reading the result. The selected angle misses the inside wall. The geometry returns a chord path without assigning an ID skip.
Setup
Part geometry
mm
mm
Greater than twice wall thickness.
Sound path
°
35–75° from the surface normal.
mm
m/s
Results update as you edit. Use calibrated measurements.
Inspection readout
SI units- Flaw depth
- 6.3551mm
- Surface dist.
- 42.889mm
- Half skip
- —
- Full skip
- —
Beam misses the ID
Shows the OD-to-OD chord and radial depth. An ID half or full skip is unavailable.
- Active leg / chord
- 1
- One leg or chord sound path
- 57.15mm
- Flat-plate full skip reference
- 62.354mm
- Pulse-echo round-trip time
- 24.768µs
- AWS distance correction
- 1.1496dB
- Max. angle reaching pipe ID
- 43.239°
- OD-only chord arc advance
- 59.847mm
- Pipe OD circumference
- 359.08mm
Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references