ASME V Article 4 · AWS D1.1

Third-leg echo in a thin fabrication weld

A 10 mm plate is examined with a 60° wedge. A late indication has a one-way path of 47 mm.

Reading the result. The ray has already made one full skip. The third-leg solution places the reflector at 3.5 mm depth.

Setup

Part geometry

mm

Sound path

°
35–75° from the surface normal.
mm
m/s
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Flaw depth
3.5mm
Surface dist.
40.703mm
Half skip
17.321mm
Full skip
34.641mm
Leg 3+ · pass 3

Surface distance starts at the beam exit point.

Weld section and shear pathPipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.Shear-wave mapFlat sectionActive leg progress35%Steel wallShear rayReflector
Pipe geometry is shown on an unfolded OD arc. The ray view shows up to four legs ending at the selected reflector.
Active leg / chord
3
One leg or chord sound path
20mm
Flat-plate full skip reference
34.641mm
Pulse-echo round-trip time
29.102µs
AWS distance correction
1.7008dB
Max. angle reaching pipe ID
—
OD-only chord arc advance
—
Pipe OD circumference
—

Use one-way sound path from a calibrated UT instrument. The AWS indication-rating distance term is an inch-pound screen. Verify the governing D1.1/D1.1M edition, unit convention and rounding rule. Equations and references