Worked example

Chow’s 400 cfs trapezoid

A 20 ft bottom with 2H:1V side slopes carries 400 cfs. Use Chow’s 0.0016 grade and n = 0.025 to reproduce the published uniform-flow section.

Results ↓

Inputs

Channel section
cfs
ft
Enter 0 for a triangular section. Set side slope to 0 for a rectangle.
Rise per unit run. Enter 0.0016 for a slope of 0.16%.

Hydraulic readout

Subcritical flow

Normal depth: 3.36107 ft, Critical depth: 2.14823 ft, Froude: 0.479121, Specific energy: 3.66931 ft

Channel cross section and specific energyNormal and critical elevations are shown in a cross section and against the computed specific-energy curve.NORMAL DEPTH3.3611 ftCRITICAL DEPTH2.1482 ftFROUDE0.47912SPECIFIC E3.6693 ftWetted channel sectionNormal yₙCrit. y꜀BedSpecific energy E(y)NormalMin. E꜀E →Froude screenCritical Fr = 1 · 0.47912

Calculation details

Section shape
Trapezoidal
Wetted area
89.815 ft²
Water surface width
33.4443 ft
Wetted perimeter
35.0312 ft
Hydraulic radius
2.56386 ft
Mean velocity
4.4536 ft/s
Minimum specific energy
3.06095 ft
Critical slope
0.00780654
Efficient bottom width
2.84581 ft
Efficient depth
6.02751 ft
Conveyance gain
11.3805%

Interpreting this example

Normal depth should be about 3.36 ft. The critical depth displayed uses α = 1. Compare the two stations on the specific-energy curve.

Q = A R²ᐟ³ √S₀ / n · Q² T / (g A³) = 1 · E = y + V²/(2g)

Both depths come from bracketed solutions of the full geometric equations. The efficiency comparison holds wetted area, side slope, roughness and bed slope fixed and minimizes wetted perimeter.

Manning normal depth assumes steady, uniform flow in a prismatic channel. Use the GVF tool for gradually changing depths and a separate energy or momentum calculation at controls.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet