Worked example
Chow’s 400 cfs trapezoid
A 20 ft bottom with 2H:1V side slopes carries 400 cfs. Use Chow’s 0.0016 grade and n = 0.025 to reproduce the published uniform-flow section.
Inputs
Hydraulic readout
Subcritical flow
Normal depth: 3.36107 ft, Critical depth: 2.14823 ft, Froude: 0.479121, Specific energy: 3.66931 ft
Input values
- Discharge Q
- 400 cfs
- Bottom width b
- 20 ft
- Side slope z (H:1V)
- 2
- Bed slope S₀
- 0.0016
- Manning n
- 0.025
Calculation details
- Section shape
- Trapezoidal
- Wetted area
- 89.815 ft²
- Water surface width
- 33.4443 ft
- Wetted perimeter
- 35.0312 ft
- Hydraulic radius
- 2.56386 ft
- Mean velocity
- 4.4536 ft/s
- Minimum specific energy
- 3.06095 ft
- Critical slope
- 0.00780654
- Efficient bottom width
- 2.84581 ft
- Efficient depth
- 6.02751 ft
- Conveyance gain
- 11.3805%
Interpreting this example
Normal depth should be about 3.36 ft. The critical depth displayed uses α = 1. Compare the two stations on the specific-energy curve.
Q = A R²ᐟ³ √S₀ / n · Q² T / (g A³) = 1 · E = y + V²/(2g)
Both depths come from bracketed solutions of the full geometric equations. The efficiency comparison holds wetted area, side slope, roughness and bed slope fixed and minimizes wetted perimeter.
Manning normal depth assumes steady, uniform flow in a prismatic channel. Use the GVF tool for gradually changing depths and a separate energy or momentum calculation at controls.
Worked examples
Open a case to load its inputs and interpretation.
- Concrete rectangular drainA 1.8 m concrete stormwater drain carries 4.6 m³/s with square corners and a surveyed 0.35% invert slope.
- Triangular roadside ditchA grass-lined ditch with no flat bottom has 3H:1V sides. Screen its depth at a runoff flow of 0.48 m³/s.
- Lined irrigation canalA 3.2 m main canal has 1.5H:1V lining and a 0.09% design grade. Use the design delivery of 6.8 m³/s.
- Steep flume approachA 1.1 m rectangular approach chute drops on a 3.4% grade and carries 2.1 m³/s over a smooth invert.
- Wide vegetated floodwayA broad 24 m floodway with 4H:1V banks is checked for 92 m³/s using a single representative n of 0.04.
- Efficient earth-channel sectionCompare an existing 6 m bottom with the hydraulically efficient cross section at a fixed 2H:1V side slope and 9.5 m³/s.