15 V flyback crossing into high-line DCM

Design near the conduction boundary at low line and compare behavior at a much higher DC bus.

Design inputs

Input & output
Transformer & clamp

Low-line primary ripple divided by primary peak.

View live readout ↑

Live readout

Edit inputs
Turns Nₚ:Nₛ
5.431 : 1
Primary Lₘ
409.3 µH
Drain Vₚₖ
553 V
Clamp loss
0.4439 W
Flyback drain voltage Flyback drain voltage High line · 15.4 µs Vᴅₛ Vin Drain RCD Np : Ns Drain peak553 VPlateau475 VClamp loss0.444 W
The ringing sketch shows the clamp and reflected plateaus. Ring frequency and residual overshoot depend on the physical circuit.
Drain headroom available

Drain stress includes the clamp setting at high line. Check overshoot on the bench.

Drain stress / rating553 V / 650 V

Reflected voltage / duty limit85 V / 96.26 V

Result breakdown
Primary : secondary turns5.43131 : 1
Primary magnetizing inductance409.294 µH
Low-line duty50.8982 %
Maximum reflected voltage at duty limit96.2609 V
Primary peak across line range1.78273 A
Worst primary RMS0.782093 A
Primary RMS at low line0.782093 A
Primary RMS at high line0.355045 A
Secondary peak across line range9.68253 A
Worst secondary RMS4.17215 A
Secondary RMS at low line4.17215 A
Secondary RMS at high line4.13058 A
High-line conduction modeDCM
Estimated high-line drain peak552.975 V
Drain voltage headroom97.025 V
RCD clamp dissipation0.443862 W
Clamp resistance56,956.9 Ω
Clamp capacitance5.40219 nF
Clamp ripple budget7.95 V
Estimated total converter loss budget6.66667 W

Worked calculation

Np/Ns = 85 V / (15 V + 0.65 V) = 5.43131 : 1

The same transformer enters DCM at high line. Compare low- and high-line winding RMS before budgeting copper heat.

Turns ratio & duty

Np/Ns = VOR / (Vout + Vf) | D = VOR / (Vin,min + VOR)

The reflected voltage must fit the maximum low-line duty. Low-line peak is (Pout/η)/(Vin,min·D·(1 − Krp/2)). Then Lm = Vin,min·D/(fs·Krp·Ipk).

Winding currents

Irms = √[tfrac · (Ipk² + Ipk·Ivalley + Ivalley²)/3]

Primary and secondary RMS values use their conduction intervals. The secondary waveform uses primary-referred magnetizing current scaled by Np/Ns. At high line the model permits a DCM interval. Winding parasitics and loss allocation require a transformer design check.

Leakage clamp

Pclamp = ½ · Llk · Ipk² · fs · Vclamp / (Vclamp − VOR)

Use the highest modeled primary peak. With leakage, the drain screen uses Vin,max + Vclamp + ΔVclamp/2 and requires the clamp valley to remain above VOR. With zero leakage the model uses Vin,max + VOR. R is Vclamp²/Pclamp and C is approximated as Vclamp/(R·fs·ΔVclamp). Allow headroom for leakage tolerance and residual ringing.