Flyback Transformer & RCD Clamp Calculator

Set the reflected voltage and low-line duty budget, then size the transformer and estimate drain stress and clamp heat.

Design inputs

Input & output
Transformer & clamp

Low-line primary ripple divided by primary peak.

View live readout ↑

Live readout

Edit inputs
Turns Nₚ:Nₛ
3.659 : 1
Primary Lₘ
562.7 µH
Drain Vₚₖ
551.3 V
Clamp loss
0.8349 W
Flyback drain voltage Flyback drain voltage High line · 11.8 µs Vᴅₛ Vin Drain RCD Np : Ns Drain peak551 VPlateau465 VClamp loss0.835 W
The ringing sketch shows the clamp and reflected plateaus. Ring frequency and residual overshoot depend on the physical circuit.
Drain headroom available

Drain stress includes the clamp setting at high line. Check overshoot on the bench.

Drain stress / rating551.3 V / 650 V

Reflected voltage / duty limit90 V / 97.5 V

Result breakdown
Primary : secondary turns3.65854 : 1
Primary magnetizing inductance562.65 µH
Low-line duty50 %
Maximum reflected voltage at duty limit97.5 V
Primary peak across line range1.71077 A
Worst primary RMS0.897816 A
Primary RMS at low line0.897816 A
Primary RMS at high line0.389362 A
Secondary peak across line range6.25892 A
Worst secondary RMS3.28469 A
Secondary RMS at low line3.28469 A
Secondary RMS at high line2.90774 A
High-line conduction modeCCM
Estimated high-line drain peak551.3 V
Drain voltage headroom98.7 V
RCD clamp dissipation0.834907 W
Clamp resistance35,433.9 Ω
Clamp capacitance6.64037 nF
Clamp ripple budget8.6 V
Estimated total converter loss budget7.81395 W

Formulas and assumptions

Turns ratio & duty

Np/Ns = VOR / (Vout + Vf) | D = VOR / (Vin,min + VOR)

The reflected voltage must fit the maximum low-line duty. Low-line peak is (Pout/η)/(Vin,min·D·(1 − Krp/2)). Then Lm = Vin,min·D/(fs·Krp·Ipk).

Winding currents

Irms = √[tfrac · (Ipk² + Ipk·Ivalley + Ivalley²)/3]

Primary and secondary RMS values use their conduction intervals. The secondary waveform uses primary-referred magnetizing current scaled by Np/Ns. At high line the model permits a DCM interval. Winding parasitics and loss allocation require a transformer design check.

Leakage clamp

Pclamp = ½ · Llk · Ipk² · fs · Vclamp / (Vclamp − VOR)

Use the highest modeled primary peak. With leakage, the drain screen uses Vin,max + Vclamp + ΔVclamp/2 and requires the clamp valley to remain above VOR. With zero leakage the model uses Vin,max + VOR. R is Vclamp²/Pclamp and C is approximated as Vclamp/(R·fs·ΔVclamp). Allow headroom for leakage tolerance and residual ringing.