High-Altitude Pump NPSH at 7,000 ft Elevation
Quantify the atmospheric head lost at 7,000 ft for a 20 gpm surface pump lifting water 15 ft.
Inputs
Results
Updates as you editAvailable NPSH exceeds the required value by less than the entered target margin.
- Available NPSH
- Entered NPSHr
- Required + margin
The horizontal references hold the duty-point NPSHr and margin fixed. Read NPSHr at each flow for a full curve check.
- Margin above NPSH required
- 0.67 ft
- NPSH required with target margin
- 11 ft
- Available ÷ required
- 1.08
- Site atmospheric pressure
- 11.34 psia
- Water vapor pressure
- 0.306 psia
- Vapor pressure head
- 0.71 ft
- Suction pipe and fitting loss
- 1.82 ft
- Maximum lift at target margin
- 12.67 ft
Inputs
- Design flow
- 20 gpm
- Water temperature
- 65 °F
- Site elevation
- 7,000 ft
- Suction arrangement
- Suction lift
- Vertical distance to liquid surface
- 15 ft
- Pump NPSH required
- 8 ft
- Target additional NPSH
- 3 ft
- Pipe material
- PVC Schedule 40
- Nominal pipe size
- 1½ in nominal
- Suction pipe length
- 45 ft
- 90° elbows
- 2
- Check valves
- 1
- Additional fitting K
- 0
- Measured inside diameter
- 0 in
- Darcy roughness override
- 0 in
- Local barometric pressure override
- 0 psia
- Vessel gas pressure relative to the site
- 0 psig
Worked calculation
Set the pressure at the liquid surface
Surface pressure = site atmospheric pressure + vessel gauge pressure
The site pressure is 11.34 psia and the liquid surface is at 11.34 psia, equivalent to 26.19 ft of head.
Find water vapor pressure
IAPWS saturation relation: ln(pᵥ/p𝒸) = (T𝒸/T) × Σaᵢ(1 − T/T𝒸)ᵖⁱ
65 °F water has 0.306 psia of vapor pressure, or 0.71 ft of head.
Account for liquid level and suction losses
NPSHa = surface head + signed liquid level − vapor head − suction loss
26.19 ft + (-15 ft) − 0.71 ft − 1.82 ft = 8.67 ft.
Compare with the pump and margin target
Available margin = NPSHa − NPSHr
The available margin is 0.67 ft. The entered NPSHr and margin call for 11 ft total.
What this example shows
The modeled atmospheric pressure is lower than sea level, which can use up the margin. Local station pressure can refine the standard-atmosphere estimate.
Frequently asked questions
Should I enter a weather app’s sea-level pressure at 7,000 ft?
Use local station pressure at the installation. A sea-level adjusted weather value would overstate pressure at the pump.
How can I recover suction head at a high-altitude site?
Reducing lift or fitting losses adds available head. A flooded arrangement can avoid the lift penalty if the installation permits it.