NPSH Available & Cavitation Margin Calculator
Calculate NPSH available from atmospheric pressure, temperature, suction level and friction. Compare it with the pump curve.
Inputs
Results
Updates as you editAvailable NPSH meets the entered margin at this duty point.
- Available NPSH
- Entered NPSHr
- Required + margin
The horizontal references hold the duty-point NPSHr and margin fixed. Read NPSHr at each flow for a full curve check.
- Margin above NPSH required
- 4.51 ft
- NPSH required with target margin
- 12 ft
- Available ÷ required
- 1.5
- Site atmospheric pressure
- 14.7 psia
- Water vapor pressure
- 4.747 psia
- Vapor pressure head
- 11.21 ft
- Suction pipe and fitting loss
- 1.98 ft
- Maximum lift at target margin
- 9.51 ft
Inputs
- Design flow
- 25 gpm
- Water temperature
- 160 °F
- Site elevation
- 0 ft
- Suction arrangement
- Suction lift
- Vertical distance to liquid surface
- 8 ft
- Pump NPSH required
- 9 ft
- Target additional NPSH
- 3 ft
- Pipe material
- PVC Schedule 40
- Nominal pipe size
- 1½ in nominal
- Suction pipe length
- 30 ft
- 90° elbows
- 2
- Check valves
- 1
- Additional fitting K
- 0
- Measured inside diameter
- 0 in
- Darcy roughness override
- 0 in
- Local barometric pressure override
- 0 psia
- Vessel gas pressure relative to the site
- 0 psig
Worked calculation
Set the pressure at the liquid surface
Surface pressure = site atmospheric pressure + vessel gauge pressure
The site pressure is 14.7 psia and the liquid surface is at 14.7 psia, equivalent to 34.69 ft of head.
Find water vapor pressure
IAPWS saturation relation: ln(pᵥ/p𝒸) = (T𝒸/T) × Σaᵢ(1 − T/T𝒸)ᵖⁱ
160 °F water has 4.747 psia of vapor pressure, or 11.21 ft of head.
Account for liquid level and suction losses
NPSHa = surface head + signed liquid level − vapor head − suction loss
34.69 ft + (-8 ft) − 11.21 ft − 1.98 ft = 13.51 ft.
Compare with the pump and margin target
Available margin = NPSHa − NPSHr
The available margin is 4.51 ft. The entered NPSHr and margin call for 12 ft total.
Model and assumptions
Use absolute pressure at the liquid surface
Standard atmosphere estimates local pressure from elevation. A station barometer can replace it. Vapor pressure comes from the IAPWS saturation equation and is subtracted as head at the water temperature.
Use the manufacturer’s required NPSH
NPSHr depends on flow, speed and pump model. The margin entered here is a screening target. Follow the vendor’s NPSH margin criteria and check the least favorable combination of level, pressure, temperature and flow.
Engineering references
Frequently asked questions
What is the difference between NPSHa and NPSHr?
NPSHa is supplied by the suction system. NPSHr is the pump’s published requirement at the operating point, commonly based on a measured head-drop criterion.
Do I add suction nozzle velocity head as a separate input?
This balance starts from a large liquid surface with negligible velocity and subtracts suction line losses. The resulting NPSHa already represents total suction head above vapor pressure.