Pump Horsepower, VFD & kWh Cost Calculator
Calculate water horsepower, shaft demand and electrical input. Compare VFD speeds, annual kWh and electricity cost.
Inputs
Results
Updates as you editAffinity estimates assume comparable pump efficiency and the same run hours.
- Flow ∝ speed
- Head ∝ speed²
- Power ∝ speed³
The marker shows target-speed power as a share of base power.
- Hydraulic water power
- 1.42 hp
- Brake power at pump shaft
- 2.44 hp
- Motor electrical input equivalent
- 2.77 hp
- Wire-to-water efficiency
- 49.5 %
- Target-speed flow
- 30 gpm
- Target-speed head
- 78.75 ft
- Target-speed electrical input
- 0.9 kW
- Base annual energy
- 4,266.1 kWh
- Target annual energy
- 1,799.8 kWh
- Base annual electricity cost
- 682.58 USD
- Target annual electricity cost
- 287.96 USD
- Annual cost difference
- 394.62 USD
Inputs
- Design flow
- 40 gpm
- Total dynamic head
- 140 ft
- Pump efficiency
- 58 %
- Motor efficiency
- 88 %
- Base frequency
- 60 Hz
- Target frequency
- 45 Hz
- Run time
- 8 h/day
- Operating days per year
- 250 days
- Energy tariff
- 0.16 USD/kWh
- Liquid specific gravity
- 1
- Drive efficiency
- 97 %
Worked calculation
Calculate useful water power
Pwater = ρgQH
40 gpm at 140 ft and specific gravity 1 requires 1.42 hp of hydraulic work.
Allow for pump, motor and drive losses
Pbrake = Pwater/ηpump. Pmotor = Pbrake/ηmotor. Pwire = Pmotor/ηdrive.
The shaft needs 2.44 hp. Motor input is 2.77 hp and electrical input before the drive is 2.13 kW.
Scale to the target frequency
r = f₂/f₁. Q₂ = Q₁r. H₂ = H₁r². P₂ = P₁r³.
45 Hz ÷ 60 Hz gives a speed ratio of 0.75. Target input is 0.9 kW.
Estimate annual energy and cost
Annual kWh = input kW × annual hours. Cost = kWh × tariff.
8 h/day × 250 days gives 2,000 h per year. The two speeds use 4,266.1 kWh and 1,799.8 kWh.
Model and assumptions
Follow the power through the equipment
Water power is useful fluid work. Brake power is the shaft load. Motor electrical input and drive input allow for their respective efficiencies. The calculation assumes direct coupling.
Read affinity results as comparable points
Frequency is used as a speed proxy. Q, H and P scale with the first, second and third powers of speed at corresponding points. Static head can shift the actual duty and drive efficiency can vary with load.
Engineering references
Frequently asked questions
What is wire-to-water efficiency on a VFD pump?
It is hydraulic output divided by incoming electrical power. The simplified model multiplies pump, motor and drive efficiencies.
Can I use the pump’s maximum listed GPM and maximum head together?
Use flow and head from the same point on the pump curve. Maximum head usually occurs at shutoff, where delivered flow is zero.