Power and energy

Pump Horsepower, VFD & kWh Cost Calculator

Calculate water horsepower, shaft demand and electrical input. Compare VFD speeds, annual kWh and electricity cost.

Inputs

Electrical input at base speed2.13 kW

Duty and efficiency

gpm
ft
%
%
Hz
Hz
h/day
days
Electricity and fluid
USD/kWh
Use 1.00 for water in this estimate.
%Enter 100% without a drive.

Results

Updates as you edit
Electrical input at base speed2.13 kW

Affinity estimates assume comparable pump efficiency and the same run hours.

Affinity laws at variable speed
Affinity laws at variable speedThe marker shows target-speed power as a share of base power.020406080100027.55582.5110Base speed (%)Base duty (%)Target power · 42.19 %
  • Flow ∝ speed
  • Head ∝ speed²
  • Power ∝ speed³

The marker shows target-speed power as a share of base power.

Hydraulic water power
1.42 hp
Brake power at pump shaft
2.44 hp
Motor electrical input equivalent
2.77 hp
Wire-to-water efficiency
49.5 %
Target-speed flow
30 gpm
Target-speed head
78.75 ft
Target-speed electrical input
0.9 kW
Base annual energy
4,266.1 kWh
Target annual energy
1,799.8 kWh
Base annual electricity cost
682.58 USD
Target annual electricity cost
287.96 USD
Annual cost difference
394.62 USD

Worked calculation

  1. Calculate useful water power

    Pwater = ρgQH

    40 gpm at 140 ft and specific gravity 1 requires 1.42 hp of hydraulic work.

  2. Allow for pump, motor and drive losses

    Pbrake = Pwater/ηpump. Pmotor = Pbrake/ηmotor. Pwire = Pmotor/ηdrive.

    The shaft needs 2.44 hp. Motor input is 2.77 hp and electrical input before the drive is 2.13 kW.

  3. Scale to the target frequency

    r = f₂/f₁. Q₂ = Q₁r. H₂ = H₁r². P₂ = P₁r³.

    45 Hz ÷ 60 Hz gives a speed ratio of 0.75. Target input is 0.9 kW.

  4. Estimate annual energy and cost

    Annual kWh = input kW × annual hours. Cost = kWh × tariff.

    8 h/day × 250 days gives 2,000 h per year. The two speeds use 4,266.1 kWh and 1,799.8 kWh.

Model and assumptions

Follow the power through the equipment

Water power is useful fluid work. Brake power is the shaft load. Motor electrical input and drive input allow for their respective efficiencies. The calculation assumes direct coupling.

Read affinity results as comparable points

Frequency is used as a speed proxy. Q, H and P scale with the first, second and third powers of speed at corresponding points. Static head can shift the actual duty and drive efficiency can vary with load.

Engineering references

Frequently asked questions

What is wire-to-water efficiency on a VFD pump?

It is hydraulic output divided by incoming electrical power. The simplified model multiplies pump, motor and drive efficiencies.

Can I use the pump’s maximum listed GPM and maximum head together?

Use flow and head from the same point on the pump curve. Maximum head usually occurs at shutoff, where delivered flow is zero.