Pump suction

NPSH Loss from a Small Suction Line and Strainer

Estimate suction loss for 32 gpm through a 1¼-inch line with an additional fitting K of 10 for a restricted strainer.

Inputs

NPSH available8.64 ft

Site and suction duty

gpm
°F
ft
ftUse the low operating water level relative to the pump centerline.
ftRead at actual flow and speed on the pump curve.
ft

Suction pipe and fittings

ftMeasure along the pipe, including vertical runs.
K = 0.9 each for this estimate.
K = 2.5 each for this estimate.
Sum the K values for other fittings.
inEnter 0 to use the nominal-size table.
inEnter 0 to use the material preset.
Surface pressure
psiaEnter 0 to use the elevation estimate.
psigEnter 0 for a vessel vented to atmosphere.

Results

Updates as you edit
NPSH available8.64 ft

Available NPSH is below the pump’s required NPSH at this duty point.

Available NPSH versus flow
Available NPSH versus flowThe horizontal references hold the duty-point NPSHr and margin fixed. Read NPSHr at each flow for a full curve check.09.619.228.838.448-11.67-1.917.8517.6127.37Suction flow (gpm)NPSH (ft)Entered duty · 8.64 ft
  • Available NPSH
  • Entered NPSHr
  • Required + margin

The horizontal references hold the duty-point NPSHr and margin fixed. Read NPSHr at each flow for a full curve check.

Margin above NPSH required
-1.36 ft
NPSH required with target margin
14 ft
Available ÷ required
0.86
Site atmospheric pressure
14.7 psia
Water vapor pressure
0.43 psia
Vapor pressure head
0.99 ft
Suction pipe and fitting loss
15.35 ft
Maximum lift at target margin
3.64 ft

Worked calculation

  1. Set the pressure at the liquid surface

    Surface pressure = site atmospheric pressure + vessel gauge pressure

    The site pressure is 14.7 psia and the liquid surface is at 14.7 psia, equivalent to 33.99 ft of head.

  2. Find water vapor pressure

    IAPWS saturation relation: ln(pᵥ/p𝒸) = (T𝒸/T) × Σaᵢ(1 − T/T𝒸)ᵖⁱ

    75 °F water has 0.43 psia of vapor pressure, or 0.99 ft of head.

  3. Account for liquid level and suction losses

    NPSHa = surface head + signed liquid level − vapor head − suction loss

    33.99 ft + (-9 ft) − 0.99 ft − 15.35 ft = 8.64 ft.

  4. Compare with the pump and margin target

    Available margin = NPSHa − NPSHr

    The available margin is -1.36 ft. The entered NPSHr and margin call for 14 ft total.

What this example shows

The small line and the restriction consume much of the head. Compare a larger inlet line and use actual clean and fouled strainer pressure drops for design.

Frequently asked questions

Can I enter a measured strainer pressure loss as a fitting K?

Convert the measured loss to head and divide by the pipe velocity head at that flow. Use that K only where the assumption is reasonable.

Why can a clogged strainer cause cavitation with the same tank level?

Extra inlet loss lowers absolute pressure at the pump even while the reservoir level stays constant.