Worked example · Deck framing
12×16 Floating Deck Beam and Footing Layout
The deck is 12 ft deep and 16 ft long. Two beam lines are 10 ft apart, with 2 ft of joist overhang beyond the outer beam. Each beam line has three posts and 6 in. of beam beyond each end post.
Example inputs
Worked result
Updates as you type- Table joist span
- 14 ft
- Table beam span
- 8 ft
- Estimated outer-post load
- 2,700 lb
Deck framing plan
SchematicProject inputs
- Joist backspan
- 10 ft
- Beam length along deck
- 16 ft
- Joist overhang
- 2 ft
- Equal beam bays
- 2
- Joist species
- Southern Pine #2
- Joist size
- 2 × 10
- Joist spacing on center
- 16 in
- Ground snow load
- 0 psf
- Beam ply size
- 2 × 10
- Beam plies
- 2-ply
- Inner support
- Freestanding beam
- Joist-to-beam connection
- Dropped beam
- Beam species
- Same as joists
- Beam overhang at each end
- 0.5 ft
Calculation details
- Table joist span
- 14 ft
- Table beam span
- 8 ft
- Estimated outer-post load
- 2,700 lb
- Joist positions
- 13
- Beam span between posts
- 7.5 ft
- Table joist cantilever
- 2 ft 6 in
- Beam end cantilever limit
- 22.5 in
- Effective joist span for beam table
- 10 ft
- IRC live / ground snow table
- 40 psf
- Gravity area load with dead load
- 50 psf
- Largest geometric post tributary area
- 52.5 ft²
- Outer beam reaction-equivalent width
- 7.2 ft
- Estimated outer beam line load
- 360 lb/ft
Checks and references
- Within limit
Joist span
Compare the entered backspan with 14 ft from R507.6.
- Within limit
Joist cantilever
R507.6 and the one-quarter backspan limit both apply. A backspan outside the listed cantilever columns needs a separate check.
- Within limit
Beam span
Compare each 7.5 ft bay with 8 ft from the selected R507.5 table.
- Within limit
Beam cantilever
Each beam end overhang is limited to one-quarter of the adjacent post bay.
- Within limit
Beam and joist layout
Dropped framing shows joists bearing above the beam. Verify bearing and uplift connectors.
Worked calculation
The steps use US customary units for the reference formulas.
Select the load case
Use 10 psf dead load plus the larger of 40 psf live load and 0 psf ground snow. The working surface load is 50 psf.
Look up the joist and overhang
16 in. on center selects the spacing column. A 10 ft backspan selects the cantilever columns. Joist span limit: 14 ft.
Size the outer beam bay
Use factor 1 from R507.5(5) × 10 ft = 10 ft effective span. Select the next listed cantilever ratio and the 6 ft column as a floor for short spans. Each beam bay is 7.5 ft.
Trace the gravity load to the posts
The outer support reaction uses (backspan + overhang)² ÷ (2 × backspan) = 7.2 ft equivalent width. Multiply by the surface load and largest post tributary length for 2,700 lb.
Enter valid values to see the steps for this layout.
Frequently asked questions
How many post locations does the illustrated 12×16 floating deck have?
The two support lines each show three posts, so there are six planned locations. The beam and reaction numbers apply to the outer support.
How can I carry the outer center-post reaction into a footing check?
Use the 7.2 ft reaction-equivalent width and 7.5 ft post bay to reproduce the 2,700 lb gravity estimate at 50 psf.