Worked example · Deck framing

12×16 Floating Deck Beam and Footing Layout

The deck is 12 ft deep and 16 ft long. Two beam lines are 10 ft apart, with 2 ft of joist overhang beyond the outer beam. Each beam line has three posts and 6 in. of beam beyond each end post.

Example inputs

Deck geometry
ft
Support centerline to support centerline.
ft
ft
Lumber and loads
psf
40 psf live and 10 psf dead are fixed.
Support details
ft
See results

Worked result

Updates as you type
Table joist span
14 ft
Table beam span
8 ft
Estimated outer-post load
2,700 lb

Deck framing plan

Schematic
Deck framing plan 16 ft10 ft7.5 ft bay13 joist positions · 16 in OCTwo beam lines · dropped

Calculation details

Table joist span
14 ft
Table beam span
8 ft
Estimated outer-post load
2,700 lb
Joist positions
13
Beam span between posts
7.5 ft
Table joist cantilever
2 ft 6 in
Beam end cantilever limit
22.5 in
Effective joist span for beam table
10 ft
IRC live / ground snow table
40 psf
Gravity area load with dead load
50 psf
Largest geometric post tributary area
52.5 ft²
Outer beam reaction-equivalent width
7.2 ft
Estimated outer beam line load
360 lb/ft

Checks and references

  • Within limit
    Joist span

    Compare the entered backspan with 14 ft from R507.6.

  • Within limit
    Joist cantilever

    R507.6 and the one-quarter backspan limit both apply. A backspan outside the listed cantilever columns needs a separate check.

  • Within limit
    Beam span

    Compare each 7.5 ft bay with 8 ft from the selected R507.5 table.

  • Within limit
    Beam cantilever

    Each beam end overhang is limited to one-quarter of the adjacent post bay.

  • Within limit
    Beam and joist layout

    Dropped framing shows joists bearing above the beam. Verify bearing and uplift connectors.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Select the load case

    Use 10 psf dead load plus the larger of 40 psf live load and 0 psf ground snow. The working surface load is 50 psf.

  2. Look up the joist and overhang

    16 in. on center selects the spacing column. A 10 ft backspan selects the cantilever columns. Joist span limit: 14 ft.

  3. Size the outer beam bay

    Use factor 1 from R507.5(5) × 10 ft = 10 ft effective span. Select the next listed cantilever ratio and the 6 ft column as a floor for short spans. Each beam bay is 7.5 ft.

  4. Trace the gravity load to the posts

    The outer support reaction uses (backspan + overhang)² ÷ (2 × backspan) = 7.2 ft equivalent width. Multiply by the surface load and largest post tributary length for 2,700 lb.

Frequently asked questions

How many post locations does the illustrated 12×16 floating deck have?

The two support lines each show three posts, so there are six planned locations. The beam and reaction numbers apply to the outer support.

How can I carry the outer center-post reaction into a footing check?

Use the 7.2 ft reaction-equivalent width and 7.5 ft post bay to reproduce the 2,700 lb gravity estimate at 50 psf.

Other calculators