Worked example · Deck framing

2×12 Douglas Fir-Larch Deck Joists at 50 psf Ground Snow

A snowy site has a confirmed 50 psf ground-snow input for the deck table. The 2×12 joists span 14 ft between supports and continue 2 ft beyond the dropped beam.

Example inputs

Deck geometry
ft
Support centerline to support centerline.
ft
ft
Lumber and loads
psf
40 psf live and 10 psf dead are fixed.
Support details
ft
See results

Worked result

Updates as you type
Table joist span
15 ft 5 in
Table beam span
9 ft 10 in
Estimated outer-post load
4,663 lb

Deck framing plan

Schematic
Deck framing plan 18 ft14 ft8.5 ft bay15 joist positions · 16 in OCLedger + outer beam · dropped

Calculation details

Table joist span
15 ft 5 in
Table beam span
9 ft 10 in
Estimated outer-post load
4,663 lb
Joist positions
15
Beam span between posts
8.5 ft
Table joist cantilever
3 ft 6 in
Beam end cantilever limit
25.5 in
Effective joist span for beam table
12.6 ft
IRC live / ground snow table
50 psf
Gravity area load with dead load
60 psf
Largest geometric post tributary area
76.5 ft²
Outer beam reaction-equivalent width
9.14 ft
Estimated outer beam line load
548.57 lb/ft

Checks and references

  • Within limit
    Joist span

    Compare the entered backspan with 15 ft 5 in from R507.6.

  • Within limit
    Joist cantilever

    R507.6 and the one-quarter backspan limit both apply. A backspan outside the listed cantilever columns needs a separate check.

  • Within limit
    Beam span

    Compare each 8.5 ft bay with 9 ft 10 in from the selected R507.5 table.

  • Within limit
    Beam cantilever

    Each beam end overhang is limited to one-quarter of the adjacent post bay.

  • Within limit
    Beam and joist layout

    Dropped framing shows joists bearing above the beam. Verify bearing and uplift connectors.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Select the load case

    Use 10 psf dead load plus the larger of 40 psf live load and 50 psf ground snow. The working surface load is 60 psf.

  2. Look up the joist and overhang

    16 in. on center selects the spacing column. A 14 ft backspan selects the cantilever columns. Joist span limit: 15 ft 5 in.

  3. Size the outer beam bay

    Use factor 0.9 from R507.5(5) × 14 ft = 12.6 ft effective span. Select the next listed cantilever ratio and the 6 ft column as a floor for short spans. Each beam bay is 8.5 ft.

  4. Trace the gravity load to the posts

    The outer support reaction uses (backspan + overhang)² ÷ (2 × backspan) = 9.14 ft equivalent width. Multiply by the surface load and largest post tributary length for 4,663 lb.

Frequently asked questions

What joist span is listed for a Douglas Fir-Larch 2×12 at 16 in. OC under 50 psf snow?

The 2021 IRC grouped 50 psf row gives 15 ft 5 in. at 16 in. on center.

Why does the 50 psf snow example use 60 psf for gravity load?

The selected snow load governs over 40 psf live load. The modeled deck surface adds 10 psf dead load.

Other calculators