Worked example · Deck framing
2×12 Douglas Fir-Larch Deck Joists at 50 psf Ground Snow
A snowy site has a confirmed 50 psf ground-snow input for the deck table. The 2×12 joists span 14 ft between supports and continue 2 ft beyond the dropped beam.
Example inputs
Worked result
Updates as you type- Table joist span
- 15 ft 5 in
- Table beam span
- 9 ft 10 in
- Estimated outer-post load
- 4,663 lb
Deck framing plan
SchematicProject inputs
- Joist backspan
- 14 ft
- Beam length along deck
- 18 ft
- Joist overhang
- 2 ft
- Equal beam bays
- 2
- Joist species
- Douglas Fir-Larch #2
- Joist size
- 2 × 12
- Joist spacing on center
- 16 in
- Ground snow load
- 50 psf
- Beam ply size
- 2 × 12
- Beam plies
- 3-ply
- Inner support
- Attached ledger
- Joist-to-beam connection
- Dropped beam
- Beam species
- Same as joists
- Beam overhang at each end
- 0.5 ft
Calculation details
- Table joist span
- 15 ft 5 in
- Table beam span
- 9 ft 10 in
- Estimated outer-post load
- 4,663 lb
- Joist positions
- 15
- Beam span between posts
- 8.5 ft
- Table joist cantilever
- 3 ft 6 in
- Beam end cantilever limit
- 25.5 in
- Effective joist span for beam table
- 12.6 ft
- IRC live / ground snow table
- 50 psf
- Gravity area load with dead load
- 60 psf
- Largest geometric post tributary area
- 76.5 ft²
- Outer beam reaction-equivalent width
- 9.14 ft
- Estimated outer beam line load
- 548.57 lb/ft
Checks and references
- Within limit
Joist span
Compare the entered backspan with 15 ft 5 in from R507.6.
- Within limit
Joist cantilever
R507.6 and the one-quarter backspan limit both apply. A backspan outside the listed cantilever columns needs a separate check.
- Within limit
Beam span
Compare each 8.5 ft bay with 9 ft 10 in from the selected R507.5 table.
- Within limit
Beam cantilever
Each beam end overhang is limited to one-quarter of the adjacent post bay.
- Within limit
Beam and joist layout
Dropped framing shows joists bearing above the beam. Verify bearing and uplift connectors.
Worked calculation
The steps use US customary units for the reference formulas.
Select the load case
Use 10 psf dead load plus the larger of 40 psf live load and 50 psf ground snow. The working surface load is 60 psf.
Look up the joist and overhang
16 in. on center selects the spacing column. A 14 ft backspan selects the cantilever columns. Joist span limit: 15 ft 5 in.
Size the outer beam bay
Use factor 0.9 from R507.5(5) × 14 ft = 12.6 ft effective span. Select the next listed cantilever ratio and the 6 ft column as a floor for short spans. Each beam bay is 8.5 ft.
Trace the gravity load to the posts
The outer support reaction uses (backspan + overhang)² ÷ (2 × backspan) = 9.14 ft equivalent width. Multiply by the surface load and largest post tributary length for 4,663 lb.
Enter valid values to see the steps for this layout.
Frequently asked questions
What joist span is listed for a Douglas Fir-Larch 2×12 at 16 in. OC under 50 psf snow?
The 2021 IRC grouped 50 psf row gives 15 ft 5 in. at 16 in. on center.
Why does the 50 psf snow example use 60 psf for gravity load?
The selected snow load governs over 40 psf live load. The modeled deck surface adds 10 psf dead load.