Worked example · Deck framing
2×8 Pressure-Treated Southern Pine Deck Joist Span at 16 in. OC
A deck crew wants to use 2×8 pressure-treated Southern Pine joists with 16 in. spacing and a flush outside edge. Start at the published live-load span limit and compare the beam bays separately.
Example inputs
Worked result
Updates as you type- Table joist span
- 11 ft 10 in
- Table beam span
- 9 ft 1 in
- Estimated outer-post load
- 1,775 lb
Deck framing plan
SchematicProject inputs
- Joist backspan
- 11.8333 ft
- Beam length along deck
- 12 ft
- Joist overhang
- 0 ft
- Equal beam bays
- 2
- Joist species
- Southern Pine #2
- Joist size
- 2 × 8
- Joist spacing on center
- 16 in
- Ground snow load
- 0 psf
- Beam ply size
- 2 × 10
- Beam plies
- 2-ply
- Inner support
- Attached ledger
- Joist-to-beam connection
- Dropped beam
- Beam species
- Same as joists
- Beam overhang at each end
- 0 ft
Calculation details
- Table joist span
- 11 ft 10 in
- Table beam span
- 9 ft 1 in
- Estimated outer-post load
- 1,775 lb
- Joist positions
- 10
- Beam span between posts
- 6 ft
- Table joist cantilever
- 2 ft 3 in
- Beam end cantilever limit
- 18 in
- Effective joist span for beam table
- 7.81 ft
- IRC live / ground snow table
- 40 psf
- Gravity area load with dead load
- 50 psf
- Largest geometric post tributary area
- 35.5 ft²
- Outer beam reaction-equivalent width
- 5.92 ft
- Estimated outer beam line load
- 295.83 lb/ft
Checks and references
- Within limit
Joist span
Compare the entered backspan with 11 ft 10 in from R507.6.
- Within limit
Joist cantilever
The joists end at the beam.
- Within limit
Beam span
Compare each 6 ft bay with 9 ft 1 in from the selected R507.5 table.
- Within limit
Beam cantilever
Each beam end overhang is limited to one-quarter of the adjacent post bay.
- Within limit
Beam and joist layout
Dropped framing shows joists bearing above the beam. Verify bearing and uplift connectors.
Worked calculation
The steps use US customary units for the reference formulas.
Select the load case
Use 10 psf dead load plus the larger of 40 psf live load and 0 psf ground snow. The working surface load is 50 psf.
Look up the joist and overhang
16 in. on center selects the spacing column. A 11.83 ft backspan selects the cantilever columns. Joist span limit: 11 ft 10 in.
Size the outer beam bay
Use factor 0.66 from R507.5(5) × 11.83 ft = 7.81 ft effective span. Select the next listed cantilever ratio and the 6 ft column as a floor for short spans. Each beam bay is 6 ft.
Trace the gravity load to the posts
The outer support reaction uses (backspan + overhang)² ÷ (2 × backspan) = 5.92 ft equivalent width. Multiply by the surface load and largest post tributary length for 1,775 lb.
Enter valid values to see the steps for this layout.
Frequently asked questions
What span does a Southern Pine #2 2×8 get at 16 in. on center?
The 40 psf live-load row in 2021 IRC R507.6 gives 11 ft 10 in. for this grade, species and spacing.
Where do I measure a backspan when the outer beam is dropped?
Use the support centerlines for the model and confirm the bearing locations against the matching IRC framing detail.