Worked example · Deck framing

2×8 Pressure-Treated Southern Pine Deck Joist Span at 16 in. OC

A deck crew wants to use 2×8 pressure-treated Southern Pine joists with 16 in. spacing and a flush outside edge. Start at the published live-load span limit and compare the beam bays separately.

Example inputs

Deck geometry
ft
Support centerline to support centerline.
ft
ft
Lumber and loads
psf
40 psf live and 10 psf dead are fixed.
Support details
ft
See results

Worked result

Updates as you type
Table joist span
11 ft 10 in
Table beam span
9 ft 1 in
Estimated outer-post load
1,775 lb

Deck framing plan

Schematic
Deck framing plan 12 ft11.83 ft6 ft bay10 joist positions · 16 in OCLedger + outer beam · dropped

Calculation details

Table joist span
11 ft 10 in
Table beam span
9 ft 1 in
Estimated outer-post load
1,775 lb
Joist positions
10
Beam span between posts
6 ft
Table joist cantilever
2 ft 3 in
Beam end cantilever limit
18 in
Effective joist span for beam table
7.81 ft
IRC live / ground snow table
40 psf
Gravity area load with dead load
50 psf
Largest geometric post tributary area
35.5 ft²
Outer beam reaction-equivalent width
5.92 ft
Estimated outer beam line load
295.83 lb/ft

Checks and references

  • Within limit
    Joist span

    Compare the entered backspan with 11 ft 10 in from R507.6.

  • Within limit
    Joist cantilever

    The joists end at the beam.

  • Within limit
    Beam span

    Compare each 6 ft bay with 9 ft 1 in from the selected R507.5 table.

  • Within limit
    Beam cantilever

    Each beam end overhang is limited to one-quarter of the adjacent post bay.

  • Within limit
    Beam and joist layout

    Dropped framing shows joists bearing above the beam. Verify bearing and uplift connectors.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Select the load case

    Use 10 psf dead load plus the larger of 40 psf live load and 0 psf ground snow. The working surface load is 50 psf.

  2. Look up the joist and overhang

    16 in. on center selects the spacing column. A 11.83 ft backspan selects the cantilever columns. Joist span limit: 11 ft 10 in.

  3. Size the outer beam bay

    Use factor 0.66 from R507.5(5) × 11.83 ft = 7.81 ft effective span. Select the next listed cantilever ratio and the 6 ft column as a floor for short spans. Each beam bay is 6 ft.

  4. Trace the gravity load to the posts

    The outer support reaction uses (backspan + overhang)² ÷ (2 × backspan) = 5.92 ft equivalent width. Multiply by the surface load and largest post tributary length for 1,775 lb.

Frequently asked questions

What span does a Southern Pine #2 2×8 get at 16 in. on center?

The 40 psf live-load row in 2021 IRC R507.6 gives 11 ft 10 in. for this grade, species and spacing.

Where do I measure a backspan when the outer beam is dropped?

Use the support centerlines for the model and confirm the bearing locations against the matching IRC framing detail.

Other calculators