Worked example · Deck framing

Flush Beam for 10 ft Hem-Fir Deck Joists

The joists hang between an attached ledger and a flush 2×8 beam. The Hem-Fir joists and beam are the same depth, and the 12 ft beam has two 6 ft post bays.

Example inputs

Deck geometry
ft
Support centerline to support centerline.
ft
ft
Lumber and loads
psf
40 psf live and 10 psf dead are fixed.
Support details
ft
See results

Worked result

Updates as you type
Table joist span
11 ft 1 in
Table beam span
7 ft 10 in
Estimated outer-post load
1,500 lb

Deck framing plan

Schematic
Deck framing plan 12 ft10 ft6 ft bay10 joist positions · 16 in OCLedger + outer beam · flush

Calculation details

Table joist span
11 ft 1 in
Table beam span
7 ft 10 in
Estimated outer-post load
1,500 lb
Joist positions
10
Beam span between posts
6 ft
Table joist cantilever
2 ft 3 in
Beam end cantilever limit
18 in
Effective joist span for beam table
6.6 ft
IRC live / ground snow table
40 psf
Gravity area load with dead load
50 psf
Largest geometric post tributary area
30 ft²
Outer beam reaction-equivalent width
5 ft
Estimated outer beam line load
250 lb/ft

Checks and references

  • Within limit
    Joist span

    Compare the entered backspan with 11 ft 1 in from R507.6.

  • Within limit
    Joist cantilever

    The joists end at the beam.

  • Within limit
    Beam span

    Compare each 6 ft bay with 7 ft 10 in from the selected R507.5 table.

  • Within limit
    Beam cantilever

    Each beam end overhang is limited to one-quarter of the adjacent post bay.

  • Within limit
    Beam and joist layout

    Flush framing uses hangers at the beam face and a beam at least as deep as the joists.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Select the load case

    Use 10 psf dead load plus the larger of 40 psf live load and 0 psf ground snow. The working surface load is 50 psf.

  2. Look up the joist and overhang

    16 in. on center selects the spacing column. A 10 ft backspan selects the cantilever columns. Joist span limit: 11 ft 1 in.

  3. Size the outer beam bay

    Use factor 0.66 from R507.5(5) × 10 ft = 6.6 ft effective span. Select the next listed cantilever ratio and the 6 ft column as a floor for short spans. Each beam bay is 6 ft.

  4. Trace the gravity load to the posts

    The outer support reaction uses (backspan + overhang)² ÷ (2 × backspan) = 5 ft equivalent width. Multiply by the surface load and largest post tributary length for 1,500 lb.

Frequently asked questions

How deep should the beam be for a flush 2×8 joist layout?

R507.5 calls for a flush beam at least as deep as the intersecting joists. This worked layout uses 2×8s for both.

Can the illustrated flush joists project out past the beam?

In this face-hanger detail the joists terminate at the flush beam. A projecting joist tail requires a different support detail.

Other calculators