Worked example · Deck framing
Flush Beam for 10 ft Hem-Fir Deck Joists
The joists hang between an attached ledger and a flush 2×8 beam. The Hem-Fir joists and beam are the same depth, and the 12 ft beam has two 6 ft post bays.
Example inputs
Worked result
Updates as you type- Table joist span
- 11 ft 1 in
- Table beam span
- 7 ft 10 in
- Estimated outer-post load
- 1,500 lb
Deck framing plan
SchematicProject inputs
- Joist backspan
- 10 ft
- Beam length along deck
- 12 ft
- Joist overhang
- 0 ft
- Equal beam bays
- 2
- Joist species
- Hem-Fir #2
- Joist size
- 2 × 8
- Joist spacing on center
- 16 in
- Ground snow load
- 0 psf
- Beam ply size
- 2 × 8
- Beam plies
- 2-ply
- Inner support
- Attached ledger
- Joist-to-beam connection
- Flush beam
- Beam species
- Same as joists
- Beam overhang at each end
- 0 ft
Calculation details
- Table joist span
- 11 ft 1 in
- Table beam span
- 7 ft 10 in
- Estimated outer-post load
- 1,500 lb
- Joist positions
- 10
- Beam span between posts
- 6 ft
- Table joist cantilever
- 2 ft 3 in
- Beam end cantilever limit
- 18 in
- Effective joist span for beam table
- 6.6 ft
- IRC live / ground snow table
- 40 psf
- Gravity area load with dead load
- 50 psf
- Largest geometric post tributary area
- 30 ft²
- Outer beam reaction-equivalent width
- 5 ft
- Estimated outer beam line load
- 250 lb/ft
Checks and references
- Within limit
Joist span
Compare the entered backspan with 11 ft 1 in from R507.6.
- Within limit
Joist cantilever
The joists end at the beam.
- Within limit
Beam span
Compare each 6 ft bay with 7 ft 10 in from the selected R507.5 table.
- Within limit
Beam cantilever
Each beam end overhang is limited to one-quarter of the adjacent post bay.
- Within limit
Beam and joist layout
Flush framing uses hangers at the beam face and a beam at least as deep as the joists.
Worked calculation
The steps use US customary units for the reference formulas.
Select the load case
Use 10 psf dead load plus the larger of 40 psf live load and 0 psf ground snow. The working surface load is 50 psf.
Look up the joist and overhang
16 in. on center selects the spacing column. A 10 ft backspan selects the cantilever columns. Joist span limit: 11 ft 1 in.
Size the outer beam bay
Use factor 0.66 from R507.5(5) × 10 ft = 6.6 ft effective span. Select the next listed cantilever ratio and the 6 ft column as a floor for short spans. Each beam bay is 6 ft.
Trace the gravity load to the posts
The outer support reaction uses (backspan + overhang)² ÷ (2 × backspan) = 5 ft equivalent width. Multiply by the surface load and largest post tributary length for 1,500 lb.
Enter valid values to see the steps for this layout.
Frequently asked questions
How deep should the beam be for a flush 2×8 joist layout?
R507.5 calls for a flush beam at least as deep as the intersecting joists. This worked layout uses 2×8s for both.
Can the illustrated flush joists project out past the beam?
In this face-hanger detail the joists terminate at the flush beam. A projecting joist tail requires a different support detail.