Worked example · Deck framing

Double 2×10 Deck Beam with a 12 ft Effective Joist Span

A deck sketch puts a double 2×10 Southern Pine beam under 2×12 joists. The joists have a 12 ft backspan and a 3 ft overhang. The 16 ft beam has two equal post bays.

Example inputs

Deck geometry
ft
Support centerline to support centerline.
ft
ft
Lumber and loads
psf
40 psf live and 10 psf dead are fixed.
Support details
ft
See results

Worked result

Updates as you type
Table joist span
16 ft 6 in
Table beam span
7 ft 4 in
Estimated outer-post load
3,750 lb

Deck framing plan

Schematic
Deck framing plan 16 ft12 ft8 ft bay13 joist positions · 16 in OCLedger + outer beam · dropped

Calculation details

Table joist span
16 ft 6 in
Table beam span
7 ft 4 in
Estimated outer-post load
3,750 lb
Joist positions
13
Beam span between posts
8 ft
Table joist cantilever
3 ft
Beam end cantilever limit
24 in
Effective joist span for beam table
12 ft
IRC live / ground snow table
40 psf
Gravity area load with dead load
50 psf
Largest geometric post tributary area
72 ft²
Outer beam reaction-equivalent width
9.38 ft
Estimated outer beam line load
468.75 lb/ft

Checks and references

  • Within limit
    Joist span

    Compare the entered backspan with 16 ft 6 in from R507.6.

  • Within limit
    Joist cantilever

    R507.6 and the one-quarter backspan limit both apply. A backspan outside the listed cantilever columns needs a separate check.

  • Review
    Beam span

    Compare each 8 ft bay with 7 ft 4 in from the selected R507.5 table.

  • Within limit
    Beam cantilever

    Each beam end overhang is limited to one-quarter of the adjacent post bay.

  • Within limit
    Beam and joist layout

    Dropped framing shows joists bearing above the beam. Verify bearing and uplift connectors.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Select the load case

    Use 10 psf dead load plus the larger of 40 psf live load and 0 psf ground snow. The working surface load is 50 psf.

  2. Look up the joist and overhang

    16 in. on center selects the spacing column. A 12 ft backspan selects the cantilever columns. Joist span limit: 16 ft 6 in.

  3. Size the outer beam bay

    Use factor 1 from R507.5(5) × 12 ft = 12 ft effective span. Select the next listed cantilever ratio and the 6 ft column as a floor for short spans. Each beam bay is 8 ft.

  4. Trace the gravity load to the posts

    The outer support reaction uses (backspan + overhang)² ÷ (2 × backspan) = 9.38 ft equivalent width. Multiply by the surface load and largest post tributary length for 3,750 lb.

Frequently asked questions

How far can this double Southern Pine 2×10 beam span at a 12 ft effective joist length?

The R507.5(1) live-load row gives 7 ft 4 in. at that effective length.

What happens if an 8 ft post bay exceeds the double-beam table value?

Review closer post spacing or a different beam row, then recheck the post and footing layout and the beam connections.

Other calculators