Worked example · Deck framing

2×10 Deck Joist Cantilever with a 10 ft Backspan

The deck edge projects 30 in. beyond a dropped beam. A 10 ft backspan and Southern Pine No. 2 2×10 joists put the tail at one-quarter of the backspan.

Example inputs

Deck geometry
ft
Support centerline to support centerline.
ft
ft
Lumber and loads
psf
40 psf live and 10 psf dead are fixed.
Support details
ft
See results

Worked result

Updates as you type
Table joist span
14 ft
Table beam span
8 ft
Estimated outer-post load
1,953 lb

Deck framing plan

Schematic
Deck framing plan 16 ft10 ft5 ft bay13 joist positions · 16 in OCLedger + outer beam · dropped

Calculation details

Table joist span
14 ft
Table beam span
8 ft
Estimated outer-post load
1,953 lb
Joist positions
13
Beam span between posts
5 ft
Table joist cantilever
2 ft 6 in
Beam end cantilever limit
15 in
Effective joist span for beam table
10 ft
IRC live / ground snow table
40 psf
Gravity area load with dead load
50 psf
Largest geometric post tributary area
37.5 ft²
Outer beam reaction-equivalent width
7.81 ft
Estimated outer beam line load
390.63 lb/ft

Checks and references

  • Within limit
    Joist span

    Compare the entered backspan with 14 ft from R507.6.

  • Within limit
    Joist cantilever

    R507.6 and the one-quarter backspan limit both apply. A backspan outside the listed cantilever columns needs a separate check.

  • Within limit
    Beam span

    Compare each 5 ft bay with 8 ft from the selected R507.5 table.

  • Within limit
    Beam cantilever

    Each beam end overhang is limited to one-quarter of the adjacent post bay.

  • Within limit
    Beam and joist layout

    Dropped framing shows joists bearing above the beam. Verify bearing and uplift connectors.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Select the load case

    Use 10 psf dead load plus the larger of 40 psf live load and 0 psf ground snow. The working surface load is 50 psf.

  2. Look up the joist and overhang

    16 in. on center selects the spacing column. A 10 ft backspan selects the cantilever columns. Joist span limit: 14 ft.

  3. Size the outer beam bay

    Use factor 1 from R507.5(5) × 10 ft = 10 ft effective span. Select the next listed cantilever ratio and the 6 ft column as a floor for short spans. Each beam bay is 5 ft.

  4. Trace the gravity load to the posts

    The outer support reaction uses (backspan + overhang)² ÷ (2 × backspan) = 7.81 ft equivalent width. Multiply by the surface load and largest post tributary length for 1,953 lb.

Frequently asked questions

How long is one-quarter of a 10 ft joist backspan?

One-quarter of 10 ft is 2 ft 6 in. The Southern Pine live-load row also gives 2 ft 6 in. at this backspan and size.

What does moving the deck beam inward do to the load on that beam?

An overhang adds deck load and leverage outside the support, increasing the beam reaction relative to a flush-ended joist.

Other calculators