Worked example · Stair framing

31-Inch Stair Rise at the 7¾-Inch Riser Limit

A four-riser stair is being fitted into a shallow entry. At exactly 31 in. finished rise, each riser lands on the 2021 IRC 7¾ in. maximum.

Example inputs

Finished stair dimensions
in
in
Measured from nosing to nosing.
in
Cut list details
0 uses the automatic count.
in
in
See results

Worked result

Updates as you type
Equal risers
4
Finished rise per step
7.75 in
Total tread run
2 ft 6 in

Cut stringer profile

Schematic
Cut stringer profile 2 ft 7 in2 ft 6 in7.75 in rise × 10 in tread37.8° pitch / 5.12 in throat

Calculation details

Equal risers
4
Finished rise per step
7.75 in
Total tread run
2 ft 6 in
Separate treads
3
Stair pitch
37.8°
Blondel 2R + T
25.5 in
Remaining stringer throat
5.12 in
Estimated blank per stringer
4 ft 1.14 in
Bottom riser layout cut
6.25 in
Stringer blanks to order
3

Checks and references

  • Within limit
    Riser height

    2021 IRC R311.7.5.1 limits a typical straight stair riser to 7¾ in. Measure finished elevations.

  • Within limit
    Tread depth

    R311.7.5.2 calls for a 10 in. minimum tread measured between nosings in this layout.

  • Within limit
    Headroom

    Use the smallest vertical clearance above the nosing line or landing. R311.7.2 uses 80 in.

  • Within limit
    Blondel comfort range

    A 24–26 in. band is used here as a stair proportion check.

  • Within limit
    Cut-stringer throat

    AWC DCA 6 Figure 28 uses a 5 in. minimum throat for its cut deck stringer detail.

  • Within limit
    Cut deck stringer span

    DCA 6 Figure 28 uses a 6 ft horizontal span limit for its unsupported cut-stringer detail. Check whether an intermediate support is needed.

  • Within limit
    Bottom cut

    This cut assumes separate tread stock above the cut stringer and a finished lower landing.

  • Within limit
    Rise between landings

    2021 IRC R311.7.3 limits a single flight to 151 in. of vertical rise.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Divide the finished rise

    31 in ÷ 4 risers = 7.75 in per riser. Automatic mode rounds up at 7¾ in. per riser.

  2. Set the framing square

    Use 7.75 in rise and 10 in run on the square. The upper landing forms the last step, leaving 3 separate treads and 30 in total run.

  3. Check the throat and stair pitch

    The notch consumes R × T ÷ √(R² + T²) = 6.13 in measured across the stock. The remaining throat is 5.12 in at 37.78°.

  4. Mark the bottom and estimate stock

    Deduct 1.5 in of tread thickness from the bottom rise for a 6.25 in cut. The rise/run diagonal plus 6 in trim allowance calls for 3 blanks of at least 4 ft 1.14 in each.

Frequently asked questions

Does a 31 in. finished rise divide evenly at the 7¾ in. maximum?

Yes. Four times 7¾ in. is exactly 31 in.

What happens when the measured entry rise changes to 31¼ in.?

The automatic count rises to five. Keeping four would put each finished riser above 7¾ in.

Other calculators