Worked example · Stair framing
84-Inch Basement Stair Layout with Eleven Risers
A basement floor is 84 in. below the upper finish. The stair shaft can fit 105 in. of tread run. Test that geometry with 10½ in. treads and a measured 82 in. of headroom.
Example inputs
Worked result
Updates as you type- Equal risers
- 11
- Finished rise per step
- 7.636 in
- Total tread run
- 8 ft 9 in
Cut stringer profile
SchematicProject inputs
- Total finished rise
- 84 in
- Tread depth
- 10.5 in
- Minimum measured headroom
- 82 in
- Sawn stringer stock
- 2 × 12
- Riser count override
- 0
- Finished tread thickness
- 1.5 in
- Blank trim allowance
- 8 in
- Number of stringers
- 3
Calculation details
- Equal risers
- 11
- Finished rise per step
- 7.636 in
- Total tread run
- 8 ft 9 in
- Separate treads
- 10
- Stair pitch
- 36°
- Blondel 2R + T
- 25.77 in
- Remaining stringer throat
- 5.07 in
- Estimated blank per stringer
- 11 ft 10.47 in
- Bottom riser layout cut
- 6.136 in
- Stringer blanks to order
- 3
Checks and references
- Within limit
Riser height
2021 IRC R311.7.5.1 limits a typical straight stair riser to 7¾ in. Measure finished elevations.
- Within limit
Tread depth
R311.7.5.2 calls for a 10 in. minimum tread measured between nosings in this layout.
- Within limit
Headroom
Use the smallest vertical clearance above the nosing line or landing. R311.7.2 uses 80 in.
- Within limit
Blondel comfort range
A 24–26 in. band is used here as a stair proportion check.
- Within limit
Cut-stringer throat
AWC DCA 6 Figure 28 uses a 5 in. minimum throat for its cut deck stringer detail.
- Review
Cut deck stringer span
DCA 6 Figure 28 uses a 6 ft horizontal span limit for its unsupported cut-stringer detail. Check whether an intermediate support is needed.
- Within limit
Bottom cut
This cut assumes separate tread stock above the cut stringer and a finished lower landing.
- Within limit
Rise between landings
2021 IRC R311.7.3 limits a single flight to 151 in. of vertical rise.
Worked calculation
The steps use US customary units for the reference formulas.
Divide the finished rise
84 in ÷ 11 risers = 7.636 in per riser. Automatic mode rounds up at 7¾ in. per riser.
Set the framing square
Use 7.636 in rise and 10.5 in run on the square. The upper landing forms the last step, leaving 10 separate treads and 105 in total run.
Check the throat and stair pitch
The notch consumes R × T ÷ √(R² + T²) = 6.18 in measured across the stock. The remaining throat is 5.07 in at 36.03°.
Mark the bottom and estimate stock
Deduct 1.5 in of tread thickness from the bottom rise for a 6.136 in cut. The rise/run diagonal plus 8 in trim allowance calls for 3 blanks of at least 11 ft 10.47 in each.
Enter valid values to see the steps for this layout.
Frequently asked questions
How many separate treads are in the 84 in. eleven-riser basement layout?
The floor above acts as the top landing, leaving ten separate treads at 10½ in. each.
How should I account for new basement flooring before laying out stairs?
Measure both finished elevations or include their planned finish thicknesses when calculating the total rise.