Worked example · Stair framing

84-Inch Basement Stair Layout with Eleven Risers

A basement floor is 84 in. below the upper finish. The stair shaft can fit 105 in. of tread run. Test that geometry with 10½ in. treads and a measured 82 in. of headroom.

Example inputs

Finished stair dimensions
in
in
Measured from nosing to nosing.
in
Cut list details
0 uses the automatic count.
in
in
See results

Worked result

Updates as you type
Equal risers
11
Finished rise per step
7.636 in
Total tread run
8 ft 9 in

Cut stringer profile

Schematic
Cut stringer profile 7 ft8 ft 9 in7.636 in rise × 10.5 in tread36° pitch / 5.07 in throat

Calculation details

Equal risers
11
Finished rise per step
7.636 in
Total tread run
8 ft 9 in
Separate treads
10
Stair pitch
36°
Blondel 2R + T
25.77 in
Remaining stringer throat
5.07 in
Estimated blank per stringer
11 ft 10.47 in
Bottom riser layout cut
6.136 in
Stringer blanks to order
3

Checks and references

  • Within limit
    Riser height

    2021 IRC R311.7.5.1 limits a typical straight stair riser to 7¾ in. Measure finished elevations.

  • Within limit
    Tread depth

    R311.7.5.2 calls for a 10 in. minimum tread measured between nosings in this layout.

  • Within limit
    Headroom

    Use the smallest vertical clearance above the nosing line or landing. R311.7.2 uses 80 in.

  • Within limit
    Blondel comfort range

    A 24–26 in. band is used here as a stair proportion check.

  • Within limit
    Cut-stringer throat

    AWC DCA 6 Figure 28 uses a 5 in. minimum throat for its cut deck stringer detail.

  • Review
    Cut deck stringer span

    DCA 6 Figure 28 uses a 6 ft horizontal span limit for its unsupported cut-stringer detail. Check whether an intermediate support is needed.

  • Within limit
    Bottom cut

    This cut assumes separate tread stock above the cut stringer and a finished lower landing.

  • Within limit
    Rise between landings

    2021 IRC R311.7.3 limits a single flight to 151 in. of vertical rise.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Divide the finished rise

    84 in ÷ 11 risers = 7.636 in per riser. Automatic mode rounds up at 7¾ in. per riser.

  2. Set the framing square

    Use 7.636 in rise and 10.5 in run on the square. The upper landing forms the last step, leaving 10 separate treads and 105 in total run.

  3. Check the throat and stair pitch

    The notch consumes R × T ÷ √(R² + T²) = 6.18 in measured across the stock. The remaining throat is 5.07 in at 36.03°.

  4. Mark the bottom and estimate stock

    Deduct 1.5 in of tread thickness from the bottom rise for a 6.136 in cut. The rise/run diagonal plus 8 in trim allowance calls for 3 blanks of at least 11 ft 10.47 in each.

Frequently asked questions

How many separate treads are in the 84 in. eleven-riser basement layout?

The floor above acts as the top landing, leaving ten separate treads at 10½ in. each.

How should I account for new basement flooring before laying out stairs?

Measure both finished elevations or include their planned finish thicknesses when calculating the total rise.

Other calculators