Worked example · Stair framing
36-Inch Deck Stair Stringer Layout with 5 Risers
Measure 36 in. from a finished patio to the top of deck boards. With 10 in. treads and the deck as the top landing, the example fits four separate treads into a 40 in. run.
Example inputs
Worked result
Updates as you type- Equal risers
- 5
- Finished rise per step
- 7.2 in
- Total tread run
- 3 ft 4 in
Cut stringer profile
SchematicProject inputs
- Total finished rise
- 36 in
- Tread depth
- 10 in
- Minimum measured headroom
- 84 in
- Sawn stringer stock
- 2 × 12
- Riser count override
- 0
- Finished tread thickness
- 1.5 in
- Blank trim allowance
- 6 in
- Number of stringers
- 3
Calculation details
- Equal risers
- 5
- Finished rise per step
- 7.2 in
- Total tread run
- 3 ft 4 in
- Separate treads
- 4
- Stair pitch
- 35.8°
- Blondel 2R + T
- 24.4 in
- Remaining stringer throat
- 5.41 in
- Estimated blank per stringer
- 4 ft 11.81 in
- Bottom riser layout cut
- 5.7 in
- Stringer blanks to order
- 3
Checks and references
- Within limit
Riser height
2021 IRC R311.7.5.1 limits a typical straight stair riser to 7¾ in. Measure finished elevations.
- Within limit
Tread depth
R311.7.5.2 calls for a 10 in. minimum tread measured between nosings in this layout.
- Within limit
Headroom
Use the smallest vertical clearance above the nosing line or landing. R311.7.2 uses 80 in.
- Within limit
Blondel comfort range
A 24–26 in. band is used here as a stair proportion check.
- Within limit
Cut-stringer throat
AWC DCA 6 Figure 28 uses a 5 in. minimum throat for its cut deck stringer detail.
- Within limit
Cut deck stringer span
DCA 6 Figure 28 uses a 6 ft horizontal span limit for its unsupported cut-stringer detail. Check whether an intermediate support is needed.
- Within limit
Bottom cut
This cut assumes separate tread stock above the cut stringer and a finished lower landing.
- Within limit
Rise between landings
2021 IRC R311.7.3 limits a single flight to 151 in. of vertical rise.
Worked calculation
The steps use US customary units for the reference formulas.
Divide the finished rise
36 in ÷ 5 risers = 7.2 in per riser. Automatic mode rounds up at 7¾ in. per riser.
Set the framing square
Use 7.2 in rise and 10 in run on the square. The upper landing forms the last step, leaving 4 separate treads and 40 in total run.
Check the throat and stair pitch
The notch consumes R × T ÷ √(R² + T²) = 5.84 in measured across the stock. The remaining throat is 5.41 in at 35.75°.
Mark the bottom and estimate stock
Deduct 1.5 in of tread thickness from the bottom rise for a 5.7 in cut. The rise/run diagonal plus 6 in trim allowance calls for 3 blanks of at least 4 ft 11.81 in each.
Enter valid values to see the steps for this layout.
Frequently asked questions
How tall is each riser for a 36 in. deck with five equal risers?
Each finished riser is 36 ÷ 5 = 7.2 in. Keep the same finished dimension at both landings.
What is the bottom layout cut for 1½ in. tread boards on this 36 in. stair?
Deduct 1½ in. from the 7.2 in. finished rise, leaving a 5.7 in. bottom layout cut in the modeled detail.