Worked example · Stair framing

48-Inch Deck Stair Cut List with Seven Risers

The deck surface is 48 in. above the lower landing. The layout uses six 10½ in. treads and three cut 2×12 stringers with a 6 in. trim allowance.

Example inputs

Finished stair dimensions
in
in
Measured from nosing to nosing.
in
Cut list details
0 uses the automatic count.
in
in
See results

Worked result

Updates as you type
Equal risers
7
Finished rise per step
6.857 in
Total tread run
5 ft 3 in

Cut stringer profile

Schematic
Cut stringer profile 4 ft5 ft 3 in6.857 in rise × 10.5 in tread33.1° pitch / 5.51 in throat

Calculation details

Equal risers
7
Finished rise per step
6.857 in
Total tread run
5 ft 3 in
Separate treads
6
Stair pitch
33.1°
Blondel 2R + T
24.21 in
Remaining stringer throat
5.51 in
Estimated blank per stringer
7 ft 1.2 in
Bottom riser layout cut
5.357 in
Stringer blanks to order
3

Checks and references

  • Within limit
    Riser height

    2021 IRC R311.7.5.1 limits a typical straight stair riser to 7¾ in. Measure finished elevations.

  • Within limit
    Tread depth

    R311.7.5.2 calls for a 10 in. minimum tread measured between nosings in this layout.

  • Within limit
    Headroom

    Use the smallest vertical clearance above the nosing line or landing. R311.7.2 uses 80 in.

  • Within limit
    Blondel comfort range

    A 24–26 in. band is used here as a stair proportion check.

  • Within limit
    Cut-stringer throat

    AWC DCA 6 Figure 28 uses a 5 in. minimum throat for its cut deck stringer detail.

  • Within limit
    Cut deck stringer span

    DCA 6 Figure 28 uses a 6 ft horizontal span limit for its unsupported cut-stringer detail. Check whether an intermediate support is needed.

  • Within limit
    Bottom cut

    This cut assumes separate tread stock above the cut stringer and a finished lower landing.

  • Within limit
    Rise between landings

    2021 IRC R311.7.3 limits a single flight to 151 in. of vertical rise.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Divide the finished rise

    48 in ÷ 7 risers = 6.857 in per riser. Automatic mode rounds up at 7¾ in. per riser.

  2. Set the framing square

    Use 6.857 in rise and 10.5 in run on the square. The upper landing forms the last step, leaving 6 separate treads and 63 in total run.

  3. Check the throat and stair pitch

    The notch consumes R × T ÷ √(R² + T²) = 5.74 in measured across the stock. The remaining throat is 5.51 in at 33.15°.

  4. Mark the bottom and estimate stock

    Deduct 1.5 in of tread thickness from the bottom rise for a 5.357 in cut. The rise/run diagonal plus 6 in trim allowance calls for 3 blanks of at least 7 ft 1.2 in each.

Frequently asked questions

How many tread cuts go on each stringer for a 48 in. deck stair?

Seven risers deliver six separate tread cuts where the deck serves as the top landing.

Why should I retain the exact 48 ÷ 7 rise while marking the stringer?

Rounding each rise independently can accumulate error. Check the total finished height and every tread elevation before cutting.

Other calculators