Worked example · Stair framing

72-Inch Deck Stair Layout and Low-Headroom Check

Ten risers bring the stair down 72 in., with nine 10 in. treads. An overhead beam leaves only 76 in. above the nosing line at the tightest location.

Example inputs

Finished stair dimensions
in
in
Measured from nosing to nosing.
in
Cut list details
0 uses the automatic count.
in
in
See results

Worked result

Updates as you type
Equal risers
10
Finished rise per step
7.2 in
Total tread run
7 ft 6 in

Cut stringer profile

Schematic
Cut stringer profile 6 ft7 ft 6 in7.2 in rise × 10 in tread35.8° pitch / 5.41 in throat

Calculation details

Equal risers
10
Finished rise per step
7.2 in
Total tread run
7 ft 6 in
Separate treads
9
Stair pitch
35.8°
Blondel 2R + T
24.4 in
Remaining stringer throat
5.41 in
Estimated blank per stringer
10 ft 1.26 in
Bottom riser layout cut
5.7 in
Stringer blanks to order
3

Checks and references

  • Within limit
    Riser height

    2021 IRC R311.7.5.1 limits a typical straight stair riser to 7¾ in. Measure finished elevations.

  • Within limit
    Tread depth

    R311.7.5.2 calls for a 10 in. minimum tread measured between nosings in this layout.

  • Review
    Headroom

    Use the smallest vertical clearance above the nosing line or landing. R311.7.2 uses 80 in.

  • Within limit
    Blondel comfort range

    A 24–26 in. band is used here as a stair proportion check.

  • Within limit
    Cut-stringer throat

    AWC DCA 6 Figure 28 uses a 5 in. minimum throat for its cut deck stringer detail.

  • Review
    Cut deck stringer span

    DCA 6 Figure 28 uses a 6 ft horizontal span limit for its unsupported cut-stringer detail. Check whether an intermediate support is needed.

  • Within limit
    Bottom cut

    This cut assumes separate tread stock above the cut stringer and a finished lower landing.

  • Within limit
    Rise between landings

    2021 IRC R311.7.3 limits a single flight to 151 in. of vertical rise.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Divide the finished rise

    72 in ÷ 10 risers = 7.2 in per riser. Automatic mode rounds up at 7¾ in. per riser.

  2. Set the framing square

    Use 7.2 in rise and 10 in run on the square. The upper landing forms the last step, leaving 9 separate treads and 90 in total run.

  3. Check the throat and stair pitch

    The notch consumes R × T ÷ √(R² + T²) = 5.84 in measured across the stock. The remaining throat is 5.41 in at 35.75°.

  4. Mark the bottom and estimate stock

    Deduct 1.5 in of tread thickness from the bottom rise for a 5.7 in cut. The rise/run diagonal plus 6 in trim allowance calls for 3 blanks of at least 10 ft 1.26 in each.

Frequently asked questions

How much headroom is missing from a 76 in. deck stair clearance?

The example is 4 in. below the typical 80 in. requirement in 2021 IRC R311.7.2.

Why does a 90 in. deck stringer run trigger a support review?

The selected AWC cut-stringer detail uses a 6 ft horizontal maximum. A 90 in. run needs another verified support or design approach.

Other calculators