Worked example · Stair framing

60-Inch Exterior Stair Stringer with Eight Risers

A 5 ft exterior stair fits beside a patio. Set the stair at 10 in. per tread and use the room available for a straight flight to the deck.

Example inputs

Finished stair dimensions
in
in
Measured from nosing to nosing.
in
Cut list details
0 uses the automatic count.
in
in
See results

Worked result

Updates as you type
Equal risers
8
Finished rise per step
7.5 in
Total tread run
5 ft 10 in

Cut stringer profile

Schematic
Cut stringer profile 5 ft5 ft 10 in7.5 in rise × 10 in tread36.9° pitch / 5.25 in throat

Calculation details

Equal risers
8
Finished rise per step
7.5 in
Total tread run
5 ft 10 in
Separate treads
7
Stair pitch
36.9°
Blondel 2R + T
25 in
Remaining stringer throat
5.25 in
Estimated blank per stringer
8 ft 2.2 in
Bottom riser layout cut
6 in
Stringer blanks to order
4

Checks and references

  • Within limit
    Riser height

    2021 IRC R311.7.5.1 limits a typical straight stair riser to 7¾ in. Measure finished elevations.

  • Within limit
    Tread depth

    R311.7.5.2 calls for a 10 in. minimum tread measured between nosings in this layout.

  • Within limit
    Headroom

    Use the smallest vertical clearance above the nosing line or landing. R311.7.2 uses 80 in.

  • Within limit
    Blondel comfort range

    A 24–26 in. band is used here as a stair proportion check.

  • Within limit
    Cut-stringer throat

    AWC DCA 6 Figure 28 uses a 5 in. minimum throat for its cut deck stringer detail.

  • Within limit
    Cut deck stringer span

    DCA 6 Figure 28 uses a 6 ft horizontal span limit for its unsupported cut-stringer detail. Check whether an intermediate support is needed.

  • Within limit
    Bottom cut

    This cut assumes separate tread stock above the cut stringer and a finished lower landing.

  • Within limit
    Rise between landings

    2021 IRC R311.7.3 limits a single flight to 151 in. of vertical rise.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Divide the finished rise

    60 in ÷ 8 risers = 7.5 in per riser. Automatic mode rounds up at 7¾ in. per riser.

  2. Set the framing square

    Use 7.5 in rise and 10 in run on the square. The upper landing forms the last step, leaving 7 separate treads and 70 in total run.

  3. Check the throat and stair pitch

    The notch consumes R × T ÷ √(R² + T²) = 6 in measured across the stock. The remaining throat is 5.25 in at 36.87°.

  4. Mark the bottom and estimate stock

    Deduct 1.5 in of tread thickness from the bottom rise for a 6 in cut. The rise/run diagonal plus 6 in trim allowance calls for 4 blanks of at least 8 ft 2.2 in each.

Frequently asked questions

What framing-square marks fit a 60 in. rise with eight steps?

Use 7½ in. of rise and 10 in. of run at each repeating step, then mark the special top and bottom cuts.

How does the 70 in. run compare with the DCA 6 cut-stringer detail?

It falls 2 in. below the guide’s 72 in. reference span. Confirm where bearing occurs and check the supported span at the job.

Other calculators