Worked example · Stair framing
60-Inch Exterior Stair Stringer with Eight Risers
A 5 ft exterior stair fits beside a patio. Set the stair at 10 in. per tread and use the room available for a straight flight to the deck.
Example inputs
Worked result
Updates as you type- Equal risers
- 8
- Finished rise per step
- 7.5 in
- Total tread run
- 5 ft 10 in
Cut stringer profile
SchematicProject inputs
- Total finished rise
- 60 in
- Tread depth
- 10 in
- Minimum measured headroom
- 90 in
- Sawn stringer stock
- 2 × 12
- Riser count override
- 0
- Finished tread thickness
- 1.5 in
- Blank trim allowance
- 6 in
- Number of stringers
- 4
Calculation details
- Equal risers
- 8
- Finished rise per step
- 7.5 in
- Total tread run
- 5 ft 10 in
- Separate treads
- 7
- Stair pitch
- 36.9°
- Blondel 2R + T
- 25 in
- Remaining stringer throat
- 5.25 in
- Estimated blank per stringer
- 8 ft 2.2 in
- Bottom riser layout cut
- 6 in
- Stringer blanks to order
- 4
Checks and references
- Within limit
Riser height
2021 IRC R311.7.5.1 limits a typical straight stair riser to 7¾ in. Measure finished elevations.
- Within limit
Tread depth
R311.7.5.2 calls for a 10 in. minimum tread measured between nosings in this layout.
- Within limit
Headroom
Use the smallest vertical clearance above the nosing line or landing. R311.7.2 uses 80 in.
- Within limit
Blondel comfort range
A 24–26 in. band is used here as a stair proportion check.
- Within limit
Cut-stringer throat
AWC DCA 6 Figure 28 uses a 5 in. minimum throat for its cut deck stringer detail.
- Within limit
Cut deck stringer span
DCA 6 Figure 28 uses a 6 ft horizontal span limit for its unsupported cut-stringer detail. Check whether an intermediate support is needed.
- Within limit
Bottom cut
This cut assumes separate tread stock above the cut stringer and a finished lower landing.
- Within limit
Rise between landings
2021 IRC R311.7.3 limits a single flight to 151 in. of vertical rise.
Worked calculation
The steps use US customary units for the reference formulas.
Divide the finished rise
60 in ÷ 8 risers = 7.5 in per riser. Automatic mode rounds up at 7¾ in. per riser.
Set the framing square
Use 7.5 in rise and 10 in run on the square. The upper landing forms the last step, leaving 7 separate treads and 70 in total run.
Check the throat and stair pitch
The notch consumes R × T ÷ √(R² + T²) = 6 in measured across the stock. The remaining throat is 5.25 in at 36.87°.
Mark the bottom and estimate stock
Deduct 1.5 in of tread thickness from the bottom rise for a 6 in cut. The rise/run diagonal plus 6 in trim allowance calls for 4 blanks of at least 8 ft 2.2 in each.
Enter valid values to see the steps for this layout.
Frequently asked questions
What framing-square marks fit a 60 in. rise with eight steps?
Use 7½ in. of rise and 10 in. of run at each repeating step, then mark the special top and bottom cuts.
How does the 70 in. run compare with the DCA 6 cut-stringer detail?
It falls 2 in. below the guide’s 72 in. reference span. Confirm where bearing occurs and check the supported span at the job.