WaterTreatLab

Membrane separation / Worked example

Cold-Water RO Pilot at 50% Recovery

Check a 15 gpm cold-water RO pilot with eight elements. Compare feed osmotic pressure and the surface-water flux screen.

Inputs

Membrane train
gpm
gpm
ft²
Feedwater
mg/L
%
°F

Results

US customary
Recovery
50 %
Permeate flux
15.882 GFD 26.964 LMH
Concentrate TDS
1,470 mg/L
Feed osmotic pressure
8.9186 psi 0.61491 bar
RO pressure vesselLive diagram
RO pressure vesselFlow and dissolved-solids balance across the membrane train. Feed15 gpmPermeate7.5 gpm8 active elementsConcentrate7.5 gpmSystem recovery50 %0%75% review100%
Flow and dissolved-solids balance across the membrane train.
Review the operating point
  • Flux exceeds the 14 GFD feedwater screen. Review fouling potential, SDI and the membrane supplier’s projection.
Concentration factor
2 ×
Concentrate flow
7.5 gpm
Permeate TDS
30 mg/L
Concentrate osmotic pressure
17.48 psi 1.2052 bar
Total active area
680 ft²
Flux review threshold
14 GFD 23.768 LMH

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. Feed and permeate of 15 and 7.5 gpm give 50% recovery.
  2. The 680 ft² of membrane yields about 15.88 GFD. This exceeds the example’s 14 GFD screen.
  3. A 30 mg/L permeate stream leaves the other half of the flow at 1,470 mg/L.

More worked examples

Equations & conventions

Water balance
R = Qₚ / Q𝒻, Q𝒸 = Q𝒻 − Qₚ, CF = Q𝒻 / Q𝒸 = 1 / (1 − R)

Use simultaneous feed and permeate flows at steady state. CF is the ideal concentration factor for completely rejected solute.

Membrane flux
J = 1,440 × Qₚ / (Aₑ × N)

With gpm and ft², J is gal/(ft²·d), or GFD. One GFD is approximately 1.698 LMH. Use the active area in the membrane datasheet.

Salt balance
Cₚ = C𝒻(1 − r), C𝒸 = (Q𝒻C𝒻 − QₚCₚ) / Q𝒸

Enter system rejection as a percentage referenced to feed TDS. The concentrate TDS includes modeled salt passage.

Osmotic pressure
π ≈ 2 × 0.0831446 × Tₖ × C / 58,442.77

This gives bar with C in mg/L and assumes ideal NaCl-equivalent TDS at the entered water temperature. Ion speciation and activity change the real result.

Planning basis

The 75% system-recovery screen and 18/14/12 GFD well/surface/reuse screens are preliminary review triggers. DuPont Table 22 varies by pretreatment and feed SDI and lists separate element-level limits. AWWA M46 and the selected membrane projection provide design context.

Questions

Does the pilot’s 59 °F input correct its membrane flux?

The displayed flux is the observed permeate volume per area. Here the water temperature enters the osmotic-pressure approximation.