WaterTreatLab

Membrane separation / Worked example

85% RO Recovery and Concentrate Loading

See how a 120 gpm RO feed at 85% recovery increases concentrate TDS and trips both system recovery and flux screens.

Inputs

Membrane train
gpm
gpm
ft²
Feedwater
mg/L
%
°F

Results

US customary
Recovery
85 %
Permeate flux
18.36 GFD 31.171 LMH
Concentrate TDS
15,864 mg/L
Feed osmotic pressure
29.53 psi 2.036 bar
RO pressure vesselLive diagram
RO pressure vesselFlow and dissolved-solids balance across the membrane train. Feed120 gpmPermeate102 gpm20 active elementsConcentrate18 gpmSystem recovery85 %0%75% review100%
Flow and dissolved-solids balance across the membrane train.
Review the operating point
  • Recovery exceeds the 75% system screen. Check staging, concentrate scaling and minimum crossflow for the selected elements.
  • Flux exceeds the 18 GFD feedwater screen. Review fouling potential, SDI and the membrane supplier’s projection.
Concentration factor
6.6667 ×
Concentrate flow
18 gpm
Permeate TDS
24 mg/L
Concentrate osmotic pressure
195.19 psi 13.458 bar
Total active area
8,000 ft²
Flux review threshold
18 GFD 30.559 LMH

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. Only 18 gpm remains in the concentrate. Complete rejection would give a concentration factor of 1 ÷ 0.15 ≈ 6.67.
  2. At 99% rejection, the permeate TDS is 24 mg/L. Subtracting the passed salt gives 15,864 mg/L in the concentrate.
  3. The average flux is 18.36 GFD, also above the 18 GFD well-water screen.

More worked examples

Equations & conventions

Water balance
R = Qₚ / Q𝒻, Q𝒸 = Q𝒻 − Qₚ, CF = Q𝒻 / Q𝒸 = 1 / (1 − R)

Use simultaneous feed and permeate flows at steady state. CF is the ideal concentration factor for completely rejected solute.

Membrane flux
J = 1,440 × Qₚ / (Aₑ × N)

With gpm and ft², J is gal/(ft²·d), or GFD. One GFD is approximately 1.698 LMH. Use the active area in the membrane datasheet.

Salt balance
Cₚ = C𝒻(1 − r), C𝒸 = (Q𝒻C𝒻 − QₚCₚ) / Q𝒸

Enter system rejection as a percentage referenced to feed TDS. The concentrate TDS includes modeled salt passage.

Osmotic pressure
π ≈ 2 × 0.0831446 × Tₖ × C / 58,442.77

This gives bar with C in mg/L and assumes ideal NaCl-equivalent TDS at the entered water temperature. Ion speciation and activity change the real result.

Planning basis

The 75% system-recovery screen and 18/14/12 GFD well/surface/reuse screens are preliminary review triggers. DuPont Table 22 varies by pretreatment and feed SDI and lists separate element-level limits. AWWA M46 and the selected membrane projection provide design context.

Questions

Why does concentrate get saltier near 85% recovery?

Most salt stays in the concentrate while the remaining water fraction drops to 15%. Concentrate TDS and scaling tendency warrant closer review.