WaterTreatLab

Membrane separation / Worked example

65% Recovery on Brackish Surface Water

Evaluate a 200 gpm surface-water RO feed at 65% recovery and compare the 13 GFD permeate flux with the surface-water screen.

Inputs

Membrane train
gpm
gpm
ft²
Feedwater
mg/L
%
°F

Results

US customary
Recovery
65 %
Permeate flux
13 GFD 22.071 LMH
Concentrate TDS
3,102 mg/L
Feed osmotic pressure
13.534 psi 0.93317 bar
RO pressure vesselLive diagram
RO pressure vesselFlow and dissolved-solids balance across the membrane train. Feed200 gpmPermeate130 gpm36 active elementsConcentrate70 gpmSystem recovery65 %0%75% review100%
Flow and dissolved-solids balance across the membrane train.
Concentration factor
2.8571 ×
Concentrate flow
70 gpm
Permeate TDS
22 mg/L
Concentrate osmotic pressure
38.167 psi 2.6315 bar
Total active area
14,400 ft²
Flux review threshold
14 GFD 23.768 LMH

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. The permeate fraction is 130 ÷ 200 = 0.65. The concentrate flow is 70 gpm.
  2. Flux is 130 × 1,440 ÷ (36 × 400) = 13 GFD, below the example’s 14 GFD screening value.
  3. With 22 mg/L of permeate TDS, the concentrate is (200 × 1,100 − 130 × 22) ÷ 70 = 3,102 mg/L.

More worked examples

Equations & conventions

Water balance
R = Qₚ / Q𝒻, Q𝒸 = Q𝒻 − Qₚ, CF = Q𝒻 / Q𝒸 = 1 / (1 − R)

Use simultaneous feed and permeate flows at steady state. CF is the ideal concentration factor for completely rejected solute.

Membrane flux
J = 1,440 × Qₚ / (Aₑ × N)

With gpm and ft², J is gal/(ft²·d), or GFD. One GFD is approximately 1.698 LMH. Use the active area in the membrane datasheet.

Salt balance
Cₚ = C𝒻(1 − r), C𝒸 = (Q𝒻C𝒻 − QₚCₚ) / Q𝒸

Enter system rejection as a percentage referenced to feed TDS. The concentrate TDS includes modeled salt passage.

Osmotic pressure
π ≈ 2 × 0.0831446 × Tₖ × C / 58,442.77

This gives bar with C in mg/L and assumes ideal NaCl-equivalent TDS at the entered water temperature. Ion speciation and activity change the real result.

Planning basis

The 75% system-recovery screen and 18/14/12 GFD well/surface/reuse screens are preliminary review triggers. DuPont Table 22 varies by pretreatment and feed SDI and lists separate element-level limits. AWWA M46 and the selected membrane projection provide design context.

Questions

What data matter after checking the surface-water flux screen?