WeibullMTBFLab · Engineering calculation
JEDEC-style IC HTOL exposure
Seventy-seven ICs complete 1,000 hours of dry heat stress at 125 °C with zero failures. Use 55 °C and 0.7 eV for the assumed field mechanism.
Stress accelerates modeled exposure
Inputs
- Stress model
- Arrhenius · temperature
- Activation energy Eₐ
- 0.7 eV
- Use temperature
- 55 °C
- Stress temperature
- 125 °C
- Chamber time per device
- 1,000 h
- Test devices
- 77
- Confidence CL
- 0.9 0–1
Results
- Combined AF
- 77.64538 ×
- Field age
- 77,645.38 h
- Fleet exposure
- 5,978,694 device·h
- Upper FIT
- 385.1318
- Temperature AF
- 77.64538 ×
- Humidity AF
- 1 ×
- Field age per device
- 8.863628 yr
- Pooled field exposure
- 682.4994 device·yr
- Confidence CL
- 0.9
AFₜ = exp[(Eₐ / k) (1/Tuse − 1/Tstress)]Use 328.15 K and stress 398.15 K give 77.64538×.AFᵣₕ = (RHstress / RHuse)ⁿThe temperature-only model uses AFᵣₕ = 1.AF = AFₜ AFᵣₕ · Tpool = AF × time × devicesThe chamber run gives 77,645.38 h per device and 5,978,694 pooled device-hours.FITᵤ = 10⁹ [−ln(1−CL)] / TpoolThe upper zero-failure bound is 385.1318 FIT.