Semiconductor case

Packaged IC humidity stress with Peck

Use 85 °C and 85% relative humidity in a damp-heat chamber. The assumed field condition is 45 °C and 55% RH.

Inputs

eV
°C
°C
%
%
h
0–1
PassStress accelerates modeled exposure
Combined AF
80.9305×
Field age
80,930.5h
Fleet exposure
3,641,870device·h
Upper FIT
632.253

Acceleration by chamber temperature

Acceleration factor versus stress temperatureAcceleration · log₁₀ AF-0.21.162.5345638199Chamber temperature (°C)CombinedTemp.AF = 1

Both curves share the field temperature and activation energy. The combined curve holds the entered humidity conditions fixed.

Download

Detailed results

Temperature AF
24.9839 ×
Humidity AF
3.239305 ×
Field age per device
9.238639 yr
Pooled field exposure
415.7388 device·yr
Confidence CL
0.9

Compare the temperature-only and combined curves. The vertical separation represents the humidity multiplier on a logarithmic scale.

Formula trace

  1. AFₜ = exp[(Eₐ / k) (1/Tuse − 1/Tstress)]Use 318.15 K and stress 358.15 K give 24.9839×.
  2. AFᵣₕ = (RHstress / RHuse)ⁿThe relative-humidity ratio gives 3.239305×.
  3. AF = AFₜ AFᵣₕ · Tpool = AF × time × devicesThe chamber run gives 80,930.48 h per device and 3,641,872 pooled device-hours.
  4. FITᵤ = 10⁹ [−ln(1−CL)] / TpoolThe upper zero-failure bound is 632.2532 FIT.

Model assumptions

Equivalent exposure assumes the same failure mechanism at both stress levels. The FIT bound assumes zero failures, a constant rate for that mechanism and pooled exposure from independent devices.

Method and sources

Related examples