WeibullMTBFLab · Engineering calculation
Packaged IC humidity stress with Peck
Use 85 °C and 85% relative humidity in a damp-heat chamber. The assumed field condition is 45 °C and 55% RH.
Stress accelerates modeled exposure
Inputs
- Stress model
- Peck · temperature and humidity
- Activation energy Eₐ
- 0.79 eV
- Use temperature
- 45 °C
- Stress temperature
- 85 °C
- Use relative humidity
- 55 %
- Stress relative humidity
- 85 %
- Humidity exponent n
- 2.7
- Chamber time per device
- 1,000 h
- Test devices
- 45
- Confidence CL
- 0.9 0–1
Results
- Combined AF
- 80.93048 ×
- Field age
- 80,930.48 h
- Fleet exposure
- 3,641,872 device·h
- Upper FIT
- 632.2532
- Temperature AF
- 24.9839 ×
- Humidity AF
- 3.239305 ×
- Field age per device
- 9.238639 yr
- Pooled field exposure
- 415.7388 device·yr
- Confidence CL
- 0.9
AFₜ = exp[(Eₐ / k) (1/Tuse − 1/Tstress)]Use 318.15 K and stress 358.15 K give 24.9839×.AFᵣₕ = (RHstress / RHuse)ⁿThe relative-humidity ratio gives 3.239305×.AF = AFₜ AFᵣₕ · Tpool = AF × time × devicesThe chamber run gives 80,930.48 h per device and 3,641,872 pooled device-hours.FITᵤ = 10⁹ [−ln(1−CL)] / TpoolThe upper zero-failure bound is 632.2532 FIT.
Equivalent exposure assumes the same failure mechanism at both stress levels. The FIT bound assumes zero failures, a constant rate for that mechanism and pooled exposure from independent devices.