Pressure Tank Sizing for a 15 GPM Pump and Two-Minute Run
Calculate target drawdown and nominal bladder tank volume for a 15 gpm well pump with a two-minute runtime target.
Inputs
Results
Updates as you editThis tank meets the entered minimum run time in the no-demand refill case.
- Water in tank
The two switch points enclose the usable drawdown. Air compression is modeled as isothermal.
- Minimum nominal tank volume
- 116.3 gal
- Shortest run time (no demand)
- 2.05 min
- Refill time at entered demand
- 2.05 min
- Pump-off time at entered demand
- —
- Usable acceptance fraction
- 25.8 %
- Recommended drained pre-charge
- 38 psig
- Drawdown for run time target
- 30 gal
- Water in tank at cut-out
- 35.05 gal
Inputs
- Pressure switch
- 40 / 60 psi
- Nominal tank volume
- 119 gal
- Pump delivery at tank
- 15 gpm
- Demand while cycling
- 0 gpm
- Minimum pump run time
- 2 min
- Pre-charge setting
- 2 psi below cut-in
- Site elevation
- 0 ft
Worked calculation
Convert gauge pressure to absolute pressure
Pabs = gauge pressure + local atmospheric pressure
The cut-in, cut-out and pre-charge are 54.7 psia, 74.7 psia, 52.7 psia on an absolute basis.
Compute the water fraction at both switch points
Boyle’s law: P₀V₀ = PVair. Water fraction = max(0, 1 − P₀/P).
The water fraction increases from 3.66 % to 29.45 %, a gain of 25.8 %.
Multiply by the nominal tank volume
Drawdown = nominal tank volume × change in water fraction
119 gal × 25.8 % gives 30.7 gal of usable water.
Check run time and size the tank
Shortest refill = drawdown / pump flow. Minimum tank = pump flow × run time / usable fraction.
15 gpm over 2 min requires 30 gal of drawdown. That corresponds to 116.3 gal of nominal tank volume.
What this example shows
At 15 gpm for two minutes, the required drawdown is 30 gallons. Choose from manufacturer drawdown ratings at the chosen switch band.
Frequently asked questions
How many gallons of usable capacity does the two-minute motor target require?
At 15 gpm the water demand on the tank during refill is 30 gallons of drawdown.
Is the two-minute rule the same for every 15 gpm pump?
Run time depends on the motor and control system. Use the minimum published for your equipment.