44-Gallon Pressure Tank Drawdown at 50/70 PSI
Compare drawdown and minimum runtime when a 44-gallon bladder tank operates from 50 to 70 psi.
Inputs
Results
Updates as you editThis tank meets the entered minimum run time in the no-demand refill case.
- Water in tank
The two switch points enclose the usable drawdown. Air compression is modeled as isothermal.
- Minimum nominal tank volume
- 43.7 gal
- Shortest run time (no demand)
- 1.01 min
- Refill time at entered demand
- 1.44 min
- Pump-off time at entered demand
- 3.36 min
- Usable acceptance fraction
- 22.88 %
- Recommended drained pre-charge
- 48 psig
- Drawdown for run time target
- 10 gal
- Water in tank at cut-out
- 11.43 gal
Inputs
- Pressure switch
- 50 / 70 psi
- Nominal tank volume
- 44 gal
- Pump delivery at tank
- 10 gpm
- Demand while cycling
- 3 gpm
- Minimum pump run time
- 1 min
- Pre-charge setting
- 2 psi below cut-in
- Site elevation
- 0 ft
Worked calculation
Convert gauge pressure to absolute pressure
Pabs = gauge pressure + local atmospheric pressure
The cut-in, cut-out and pre-charge are 64.7 psia, 84.7 psia, 62.7 psia on an absolute basis.
Compute the water fraction at both switch points
Boyle’s law: P₀V₀ = PVair. Water fraction = max(0, 1 − P₀/P).
The water fraction increases from 3.09 % to 25.98 %, a gain of 22.88 %.
Multiply by the nominal tank volume
Drawdown = nominal tank volume × change in water fraction
44 gal × 22.88 % gives 10.07 gal of usable water.
Check run time and size the tank
Shortest refill = drawdown / pump flow. Minimum tank = pump flow × run time / usable fraction.
10 gpm over 1 min requires 10 gal of drawdown. That corresponds to 43.7 gal of nominal tank volume.
What this example shows
Raising both set points can reduce the usable fraction, even with the same 20 psi band. Use the switch selector to compare one tank at several pressures.
Frequently asked questions
Why do a 50/70 and a 30/50 switch give different drawdown with the same band?
Boyle’s law uses ratios of absolute pressures. A 20 psi change is a smaller fraction of the higher pressures at 50/70.
What else should be checked before increasing the switch to 70 psi?
Check pump capability and the allowable pressure of the vessel, piping and accessories. Use the product’s instructions and ratings.