Well tank sizing

44-Gallon Pressure Tank Drawdown at 50/70 PSI

Compare drawdown and minimum runtime when a 44-gallon bladder tank operates from 50 to 70 psi.

Inputs

Usable drawdown10.07 gal

Tank and pressure switch

gal
gpm
gpm
minUse the motor manufacturer’s minimum.
Pre-charge and elevation
ft

Results

Updates as you edit
Usable drawdown10.07 gal

This tank meets the entered minimum run time in the no-demand refill case.

Water in tank versus pressure
Water in tank versus pressureThe two switch points enclose the usable drawdown. Air compression is modeled as isothermal.015.6831.3647.0462.7278.403.957.911.8515.8Gauge pressure (psig)Water volume (gal)Cut-in · 1.36 galCut-out · 11.43 gal
  • Water in tank

The two switch points enclose the usable drawdown. Air compression is modeled as isothermal.

Minimum nominal tank volume
43.7 gal
Shortest run time (no demand)
1.01 min
Refill time at entered demand
1.44 min
Pump-off time at entered demand
3.36 min
Usable acceptance fraction
22.88 %
Recommended drained pre-charge
48 psig
Drawdown for run time target
10 gal
Water in tank at cut-out
11.43 gal

Worked calculation

  1. Convert gauge pressure to absolute pressure

    Pabs = gauge pressure + local atmospheric pressure

    The cut-in, cut-out and pre-charge are 64.7 psia, 84.7 psia, 62.7 psia on an absolute basis.

  2. Compute the water fraction at both switch points

    Boyle’s law: P₀V₀ = PVair. Water fraction = max(0, 1 − P₀/P).

    The water fraction increases from 3.09 % to 25.98 %, a gain of 22.88 %.

  3. Multiply by the nominal tank volume

    Drawdown = nominal tank volume × change in water fraction

    44 gal × 22.88 % gives 10.07 gal of usable water.

  4. Check run time and size the tank

    Shortest refill = drawdown / pump flow. Minimum tank = pump flow × run time / usable fraction.

    10 gpm over 1 min requires 10 gal of drawdown. That corresponds to 43.7 gal of nominal tank volume.

What this example shows

Raising both set points can reduce the usable fraction, even with the same 20 psi band. Use the switch selector to compare one tank at several pressures.

Frequently asked questions

Why do a 50/70 and a 30/50 switch give different drawdown with the same band?

Boyle’s law uses ratios of absolute pressures. A 20 psi change is a smaller fraction of the higher pressures at 50/70.

What else should be checked before increasing the switch to 70 psi?

Check pump capability and the allowable pressure of the vessel, piping and accessories. Use the product’s instructions and ratings.