Well tank sizing

Pressure Tank Pre-Charge Above a 40 PSI Cut-In

Model a measured pre-charge of 47 psi on a 40/60 switch and see where the tank runs out of water.

Inputs

Usable drawdown10.79 gal

Tank and pressure switch

gal
gpm
gpm
minUse the motor manufacturer’s minimum.
Pre-charge and elevation
psig
ft

Results

Updates as you edit
Usable drawdown10.79 gal

Pre-charge reaches or exceeds cut-in. The tank can run out of water before the pump starts.

Water in tank versus pressure
Water in tank versus pressureThe two switch points enclose the usable drawdown. Air compression is modeled as isothermal.013.4426.8840.3253.7667.204.218.4112.6216.82Gauge pressure (psig)Water volume (gal)Cut-in · 0 galCut-out · 10.79 gal
  • Water in tank

The two switch points enclose the usable drawdown. Air compression is modeled as isothermal.

Minimum nominal tank volume
137.9 gal
Shortest run time (no demand)
0.9 min
Refill time at entered demand
1.54 min
Pump-off time at entered demand
2.16 min
Usable acceptance fraction
17.4 %
Recommended drained pre-charge
38 psig
Drawdown for run time target
24 gal
Water in tank at cut-out
10.79 gal

Worked calculation

  1. Convert gauge pressure to absolute pressure

    Pabs = gauge pressure + local atmospheric pressure

    The cut-in, cut-out and pre-charge are 54.7 psia, 74.7 psia, 61.7 psia on an absolute basis.

  2. Compute the water fraction at both switch points

    Boyle’s law: P₀V₀ = PVair. Water fraction = max(0, 1 − P₀/P).

    The water fraction increases from 0 % to 17.4 %, a gain of 17.4 %.

  3. Multiply by the nominal tank volume

    Drawdown = nominal tank volume × change in water fraction

    62 gal × 17.4 % gives 10.79 gal of usable water.

  4. Check run time and size the tank

    Shortest refill = drawdown / pump flow. Minimum tank = pump flow × run time / usable fraction.

    12 gpm over 2 min requires 24 gal of drawdown. That corresponds to 137.9 gal of nominal tank volume.

What this example shows

The water fraction reaches zero before pressure reaches the 40 psi cut-in. Verify tank and switch readings against the manufacturer procedure with the water side unpressurized.

Frequently asked questions

What does 47 psi pre-charge do with a 40 psi cut-in?

The air can displace all stored water before the pressure switch calls for the pump, creating a gap in delivery.

When should I measure pre-charge on this bladder tank?

Follow the tank instructions with the pump de-energized and all water-side pressure relieved.