Pressure Tank Pre-Charge Above a 40 PSI Cut-In
Model a measured pre-charge of 47 psi on a 40/60 switch and see where the tank runs out of water.
Inputs
Results
Updates as you editPre-charge reaches or exceeds cut-in. The tank can run out of water before the pump starts.
- Water in tank
The two switch points enclose the usable drawdown. Air compression is modeled as isothermal.
- Minimum nominal tank volume
- 137.9 gal
- Shortest run time (no demand)
- 0.9 min
- Refill time at entered demand
- 1.54 min
- Pump-off time at entered demand
- 2.16 min
- Usable acceptance fraction
- 17.4 %
- Recommended drained pre-charge
- 38 psig
- Drawdown for run time target
- 24 gal
- Water in tank at cut-out
- 10.79 gal
Inputs
- Pressure switch
- 40 / 60 psi
- Nominal tank volume
- 62 gal
- Pump delivery at tank
- 12 gpm
- Demand while cycling
- 5 gpm
- Minimum pump run time
- 2 min
- Pre-charge setting
- Measured pre-charge
- Drained tank pre-charge
- 47 psig
- Site elevation
- 0 ft
Worked calculation
Convert gauge pressure to absolute pressure
Pabs = gauge pressure + local atmospheric pressure
The cut-in, cut-out and pre-charge are 54.7 psia, 74.7 psia, 61.7 psia on an absolute basis.
Compute the water fraction at both switch points
Boyle’s law: P₀V₀ = PVair. Water fraction = max(0, 1 − P₀/P).
The water fraction increases from 0 % to 17.4 %, a gain of 17.4 %.
Multiply by the nominal tank volume
Drawdown = nominal tank volume × change in water fraction
62 gal × 17.4 % gives 10.79 gal of usable water.
Check run time and size the tank
Shortest refill = drawdown / pump flow. Minimum tank = pump flow × run time / usable fraction.
12 gpm over 2 min requires 24 gal of drawdown. That corresponds to 137.9 gal of nominal tank volume.
What this example shows
The water fraction reaches zero before pressure reaches the 40 psi cut-in. Verify tank and switch readings against the manufacturer procedure with the water side unpressurized.
Frequently asked questions
What does 47 psi pre-charge do with a 40 psi cut-in?
The air can displace all stored water before the pressure switch calls for the pump, creating a gap in delivery.
When should I measure pre-charge on this bladder tank?
Follow the tank instructions with the pump de-energized and all water-side pressure relieved.