Well tank sizing

Well Pressure Tank Drawdown & Pre-Charge Calculator

Use Boyle’s law to estimate usable drawdown, refill time and minimum tank size for a given pump and switch.

Inputs

Usable drawdown22.18 gal

Tank and pressure switch

gal
gpm
gpm
minUse the motor manufacturer’s minimum.
Pre-charge and elevation
ft

Results

Updates as you edit
Usable drawdown22.18 gal

The no-demand refill is shorter than the entered minimum pump run time.

Water in tank versus pressure
Water in tank versus pressureThe two switch points enclose the usable drawdown. Air compression is modeled as isothermal.013.4426.8840.3253.7667.208.4316.8625.333.73Gauge pressure (psig)Water volume (gal)Cut-in · 3.14 galCut-out · 25.33 gal
  • Water in tank

The two switch points enclose the usable drawdown. Air compression is modeled as isothermal.

Minimum nominal tank volume
116.3 gal
Shortest run time (no demand)
1.48 min
Refill time at entered demand
2.02 min
Pump-off time at entered demand
5.55 min
Usable acceptance fraction
25.8 %
Recommended drained pre-charge
38 psig
Drawdown for run time target
30 gal
Water in tank at cut-out
25.33 gal

Worked calculation

  1. Convert gauge pressure to absolute pressure

    Pabs = gauge pressure + local atmospheric pressure

    The cut-in, cut-out and pre-charge are 54.7 psia, 74.7 psia, 52.7 psia on an absolute basis.

  2. Compute the water fraction at both switch points

    Boyle’s law: P₀V₀ = PVair. Water fraction = max(0, 1 − P₀/P).

    The water fraction increases from 3.66 % to 29.45 %, a gain of 25.8 %.

  3. Multiply by the nominal tank volume

    Drawdown = nominal tank volume × change in water fraction

    86 gal × 25.8 % gives 22.18 gal of usable water.

  4. Check run time and size the tank

    Shortest refill = drawdown / pump flow. Minimum tank = pump flow × run time / usable fraction.

    15 gpm over 2 min requires 30 gal of drawdown. That corresponds to 116.3 gal of nominal tank volume.

Model and assumptions

Use absolute air pressure

The model adds local atmospheric pressure to each gauge value and uses Boyle’s law with an ideal isothermal air chamber. Actual usable volume varies with diaphragm geometry and manufacturer acceptance limits.

Check the shortest refill

With all outlets closed the tank receives the full pump flow. Use the motor’s minimum run time, often one or two minutes for the examples here. Set drained pre-charge according to the tank instructions.

Engineering references

Frequently asked questions

How is pressure tank drawdown different from maximum acceptance?

Drawdown is the water delivered between two switch points. Maximum acceptance is the most water the particular vessel can hold under its design conditions.

Why name the shortest and flowing refill times separately?

No-demand refill uses the entire pump flow. Competing demand leaves less flow to fill the tank, which lengthens refill or prevents cut-out.