86-Gallon Pressure Tank Drawdown at 40/60 PSI
Estimate usable drawdown and refill time for an 86-gallon bladder tank on a 40/60 psi switch and 15 gpm pump.
Inputs
Results
Updates as you editThe no-demand refill is shorter than the entered minimum pump run time.
- Water in tank
The two switch points enclose the usable drawdown. Air compression is modeled as isothermal.
- Minimum nominal tank volume
- 116.3 gal
- Shortest run time (no demand)
- 1.48 min
- Refill time at entered demand
- 2.02 min
- Pump-off time at entered demand
- 5.55 min
- Usable acceptance fraction
- 25.8 %
- Recommended drained pre-charge
- 38 psig
- Drawdown for run time target
- 30 gal
- Water in tank at cut-out
- 25.33 gal
Inputs
- Pressure switch
- 40 / 60 psi
- Nominal tank volume
- 86 gal
- Pump delivery at tank
- 15 gpm
- Demand while cycling
- 4 gpm
- Minimum pump run time
- 2 min
- Pre-charge setting
- 2 psi below cut-in
- Site elevation
- 0 ft
Worked calculation
Convert gauge pressure to absolute pressure
Pabs = gauge pressure + local atmospheric pressure
The cut-in, cut-out and pre-charge are 54.7 psia, 74.7 psia, 52.7 psia on an absolute basis.
Compute the water fraction at both switch points
Boyle’s law: P₀V₀ = PVair. Water fraction = max(0, 1 − P₀/P).
The water fraction increases from 3.66 % to 29.45 %, a gain of 25.8 %.
Multiply by the nominal tank volume
Drawdown = nominal tank volume × change in water fraction
86 gal × 25.8 % gives 22.18 gal of usable water.
Check run time and size the tank
Shortest refill = drawdown / pump flow. Minimum tank = pump flow × run time / usable fraction.
15 gpm over 2 min requires 30 gal of drawdown. That corresponds to 116.3 gal of nominal tank volume.
What this example shows
The ideal gas estimate gives around 22.2 usable gallons and 1.48 minutes of no-demand refill. Check the tank manufacturer’s rated drawdown for the exact model before selecting it.
Frequently asked questions
Is the listed 86 gallons the water I can use between pump starts?
It is nominal tank volume. The usable drawdown is the change in water volume from cut-out to cut-in.
Why can an 86-gallon tank catalogue list a somewhat different drawdown?
The ideal Boyle’s law model simplifies the diaphragm and working volume. Use the product table for its tested or rated drawdown.