20-Gallon Pressure Tank Run Time at 30/50 PSI
Check the shortest refill time for a 20-gallon well tank on a 30/50 switch with an 8 gpm pump.
Inputs
Results
Updates as you editThe no-demand refill is shorter than the entered minimum pump run time.
- Water in tank
The two switch points enclose the usable drawdown. Air compression is modeled as isothermal.
- Minimum nominal tank volume
- 27.1 gal
- Shortest run time (no demand)
- 0.74 min
- Refill time at entered demand
- 0.98 min
- Pump-off time at entered demand
- 2.95 min
- Usable acceptance fraction
- 29.53 %
- Recommended drained pre-charge
- 28 psig
- Drawdown for run time target
- 8 gal
- Water in tank at cut-out
- 6.8 gal
Inputs
- Pressure switch
- 30 / 50 psi
- Nominal tank volume
- 20 gal
- Pump delivery at tank
- 8 gpm
- Demand while cycling
- 2 gpm
- Minimum pump run time
- 1 min
- Pre-charge setting
- 2 psi below cut-in
- Site elevation
- 0 ft
Worked calculation
Convert gauge pressure to absolute pressure
Pabs = gauge pressure + local atmospheric pressure
The cut-in, cut-out and pre-charge are 44.7 psia, 64.7 psia, 42.7 psia on an absolute basis.
Compute the water fraction at both switch points
Boyle’s law: P₀V₀ = PVair. Water fraction = max(0, 1 − P₀/P).
The water fraction increases from 4.47 % to 34.01 %, a gain of 29.53 %.
Multiply by the nominal tank volume
Drawdown = nominal tank volume × change in water fraction
20 gal × 29.53 % gives 5.91 gal of usable water.
Check run time and size the tank
Shortest refill = drawdown / pump flow. Minimum tank = pump flow × run time / usable fraction.
8 gpm over 1 min requires 8 gal of drawdown. That corresponds to 27.1 gal of nominal tank volume.
What this example shows
An 8 gpm pump needs 8 gallons of drawdown to run for one minute with outlets closed. Compare that target with the modeled usable capacity.
Frequently asked questions
What drained pre-charge matches this 30/50 psi tank example?
The 2 psi offset gives 28 psig with the water side drained, subject to the tank instructions.
Why check the 20-gallon tank with no faucets running?
With no competing demand, all pump flow enters the tank. This gives the shortest refill under the constant-flow assumption.