Well tank sizing

20-Gallon Pressure Tank Run Time at 30/50 PSI

Check the shortest refill time for a 20-gallon well tank on a 30/50 switch with an 8 gpm pump.

Inputs

Usable drawdown5.91 gal

Tank and pressure switch

gal
gpm
gpm
minUse the motor manufacturer’s minimum.
Pre-charge and elevation
ft

Results

Updates as you edit
Usable drawdown5.91 gal

The no-demand refill is shorter than the entered minimum pump run time.

Water in tank versus pressure
Water in tank versus pressureThe two switch points enclose the usable drawdown. Air compression is modeled as isothermal.011.222.433.644.85602.184.366.548.71Gauge pressure (psig)Water volume (gal)Cut-in · 0.89 galCut-out · 6.8 gal
  • Water in tank

The two switch points enclose the usable drawdown. Air compression is modeled as isothermal.

Minimum nominal tank volume
27.1 gal
Shortest run time (no demand)
0.74 min
Refill time at entered demand
0.98 min
Pump-off time at entered demand
2.95 min
Usable acceptance fraction
29.53 %
Recommended drained pre-charge
28 psig
Drawdown for run time target
8 gal
Water in tank at cut-out
6.8 gal

Worked calculation

  1. Convert gauge pressure to absolute pressure

    Pabs = gauge pressure + local atmospheric pressure

    The cut-in, cut-out and pre-charge are 44.7 psia, 64.7 psia, 42.7 psia on an absolute basis.

  2. Compute the water fraction at both switch points

    Boyle’s law: P₀V₀ = PVair. Water fraction = max(0, 1 − P₀/P).

    The water fraction increases from 4.47 % to 34.01 %, a gain of 29.53 %.

  3. Multiply by the nominal tank volume

    Drawdown = nominal tank volume × change in water fraction

    20 gal × 29.53 % gives 5.91 gal of usable water.

  4. Check run time and size the tank

    Shortest refill = drawdown / pump flow. Minimum tank = pump flow × run time / usable fraction.

    8 gpm over 1 min requires 8 gal of drawdown. That corresponds to 27.1 gal of nominal tank volume.

What this example shows

An 8 gpm pump needs 8 gallons of drawdown to run for one minute with outlets closed. Compare that target with the modeled usable capacity.

Frequently asked questions

What drained pre-charge matches this 30/50 psi tank example?

The 2 psi offset gives 28 psig with the water side drained, subject to the tank instructions.

Why check the 20-gallon tank with no faucets running?

With no competing demand, all pump flow enters the tank. This gives the shortest refill under the constant-flow assumption.