Irrigation hydraulics

Maximum Run Length of a 16 mm Drip Lateral

Estimate a 16 mm outside-diameter dripline’s usable run with a 13.8 mm bore, 305 mm spacing and 2.27 L/h emitters.

Inputs

Total zone flow54.48 L/min

Zone layout

m
mm
m
L/h

Pipe bores and watering target

mm
mm
mm
%
Lateral pressure budget
kPa(g)Use pressure after the filter, regulator and mainline.
kPa(g)
mPositive uphill. The max-run estimate holds the slope constant.

Results

Updates as you edit
Total zone flow54.48 L/min

The entered pressure budget and 5 ft/s velocity screen are met.

Pressure along the critical lateral
Pressure along the critical lateralFlow drops at each outlet. The pressure model keeps each outlet at its rated flow.01122334455034.168.2102.3136.4Run distance (m)Gauge pressure (kPa(g))
  • Calculated pressure
  • Minimum outlet pressure

Flow drops at each outlet. The pressure model keeps each outlet at its rated flow.

Gross precipitation rate
9.78 mm/h
Weekly run time
183.4 min
Mainline velocity
0.94 m/s
Critical lateral inlet velocity
0.76 m/s
Critical lateral inlet flow
6.81 L/min
Outlets on critical lateral
180
Lateral friction drop
10.72 kPa
Lowest lateral pressure
113.28 kPa(g)
Estimated maximum drip run
87.8 m

Worked calculation

  1. Count outlets and total the flow

    Emitters per line = floor(run length / spacing). Zone flow = total emitters × flow per emitter.

    1,440 outlets give 54.48 L/min over 334.4 m².

  2. Turn flow into application rate

    Gross depth per hour = hourly zone volume / wetted area

    The gross rate is 9.78 mm/h and the net target is 25.4 mm per week at 85 % efficiency.

  3. Calculate the weekly run time

    Minutes per week = 60 × target depth / (gross hourly rate × efficiency)

    The weekly runtime is 183.4 min.

  4. Track pressure down the lateral

    Each segment carries the flow for its remaining outlets. Segment head loss uses Hazen–Williams.

    Friction contributes 10.72 kPa. Adding elevation gives a lowest gauge pressure of 113.28 kPa(g). At the same slope, the pressure and velocity limits allow about 87.8 m.

What this example shows

The run estimate screens the smallest pressure along the lateral and limits inlet velocity. Compare it with the emitter maker’s uniformity chart, which also accounts for actual emitter behavior.

Frequently asked questions

Why enter 13.8 mm for tubing sold as 16 mm dripline?

Use the inside bore for friction and velocity. The advertised 16 mm can describe the outside of the tubing.

Does this 16 mm max-run calculation account for sloping beds?

Enter rise over the current run. The length estimate holds that slope constant and checks pressure along the run.