Maximum Run Length of a 16 mm Drip Lateral
Estimate a 16 mm outside-diameter dripline’s usable run with a 13.8 mm bore, 305 mm spacing and 2.27 L/h emitters.
Inputs
Results
Updates as you editThe entered pressure budget and 5 ft/s velocity screen are met.
- Calculated pressure
- Minimum outlet pressure
Flow drops at each outlet. The pressure model keeps each outlet at its rated flow.
- Gross precipitation rate
- 9.78 mm/h
- Weekly run time
- 183.4 min
- Mainline velocity
- 0.94 m/s
- Critical lateral inlet velocity
- 0.76 m/s
- Critical lateral inlet flow
- 6.81 L/min
- Outlets on critical lateral
- 180
- Lateral friction drop
- 10.72 kPa
- Lowest lateral pressure
- 113.28 kPa(g)
- Estimated maximum drip run
- 87.8 m
Inputs
- Emitter type
- Inline drip
- Parallel drip laterals
- 8
- Drip lateral length
- 55 m
- Emitter spacing
- 305 mm
- Lateral row spacing
- 0.76 m
- Flow per drip emitter
- 2.27 L/h
- Mainline inside diameter
- 35 mm
- Lateral inside diameter
- 13.8 mm
- Net weekly water depth
- 25.4 mm
- Application efficiency
- 85 %
- Pressure at lateral entrance
- 124 kPa(g)
- Minimum outlet pressure
- 83 kPa(g)
- Elevation change along run
- 0 m
- Lateral Hazen–Williams C
- 150
Worked calculation
Count outlets and total the flow
Emitters per line = floor(run length / spacing). Zone flow = total emitters × flow per emitter.
1,440 outlets give 54.48 L/min over 334.4 m².
Turn flow into application rate
Gross depth per hour = hourly zone volume / wetted area
The gross rate is 9.78 mm/h and the net target is 25.4 mm per week at 85 % efficiency.
Calculate the weekly run time
Minutes per week = 60 × target depth / (gross hourly rate × efficiency)
The weekly runtime is 183.4 min.
Track pressure down the lateral
Each segment carries the flow for its remaining outlets. Segment head loss uses Hazen–Williams.
Friction contributes 10.72 kPa. Adding elevation gives a lowest gauge pressure of 113.28 kPa(g). At the same slope, the pressure and velocity limits allow about 87.8 m.
What this example shows
The run estimate screens the smallest pressure along the lateral and limits inlet velocity. Compare it with the emitter maker’s uniformity chart, which also accounts for actual emitter behavior.
Frequently asked questions
Why enter 13.8 mm for tubing sold as 16 mm dripline?
Use the inside bore for friction and velocity. The advertised 16 mm can describe the outside of the tubing.
Does this 16 mm max-run calculation account for sloping beds?
Enter rise over the current run. The length estimate holds that slope constant and checks pressure along the run.