Raised-Bed Drip Flow and Weekly Watering Time
Estimate zone flow and weekly watering minutes for ten 24 ft garden rows at 12-inch spacing and 0.5 GPH.
Inputs
Results
Updates as you editThe entered pressure budget and 5 ft/s velocity screen are met.
- Calculated pressure
- Minimum outlet pressure
Flow drops at each outlet. The pressure model keeps each outlet at its rated flow.
- Gross precipitation rate
- 0.53 in/h
- Weekly run time
- 137.1 min
- Mainline velocity
- 1.2 ft/s
- Critical lateral inlet velocity
- 0.3 ft/s
- Critical lateral inlet flow
- 0.2 gpm
- Outlets on critical lateral
- 24
- Lateral friction drop
- 4.61e-3 psi
- Lowest lateral pressure
- 16 psig
- Estimated maximum drip run
- 302 ft
Inputs
- Emitter type
- Inline drip
- Parallel drip laterals
- 10
- Drip lateral length
- 24 ft
- Emitter spacing
- 12 in
- Lateral row spacing
- 1.5 ft
- Flow per drip emitter
- 0.5 gal/h
- Mainline inside diameter
- 0.824 in
- Lateral inside diameter
- 0.52 in
- Net weekly water depth
- 1.1 in
- Application efficiency
- 90 %
- Pressure at lateral entrance
- 16 psig
- Minimum outlet pressure
- 10 psig
- Elevation change along run
- 0 ft
- Lateral Hazen–Williams C
- 150
Worked calculation
Count outlets and total the flow
Emitters per line = floor(run length / spacing). Zone flow = total emitters × flow per emitter.
240 outlets give 2 gpm over 360 ft².
Turn flow into application rate
Gross depth per hour = hourly zone volume / wetted area
The gross rate is 0.53 in/h and the net target is 1.1 in per week at 90 % efficiency.
Calculate the weekly run time
Minutes per week = 60 × target depth / (gross hourly rate × efficiency)
The weekly runtime is 137.1 min.
Track pressure down the lateral
Each segment carries the flow for its remaining outlets. Segment head loss uses Hazen–Williams.
Friction contributes 4.61e-3 psi. Adding elevation gives a lowest gauge pressure of 16 psig. At the same slope, the pressure and velocity limits allow about 302 ft.
What this example shows
The depth is averaged over the entered row-strip area. Adjust row spacing and target depth to reflect the crop and irrigated bed area.
Frequently asked questions
Which row spacing should I use if raised beds have wide aisles?
Use the ground width per dripline the intended water-depth target applies to. Exclude dry aisles from a bed-only depth target.
How do I convert the weekly raised-bed runtime to a three-day schedule?
Divide the calculated weekly minutes by three, then adjust based on soil and plant observations.