Irrigation hydraulics

Six Pop-Up Sprays on a Home Irrigation Zone

Check a six-head spray zone at 1.6 gpm per head, 1,900 ft² of turf and a 30 psi outlet target.

Inputs

Total zone flow9.6 gpm

Zone layout

gpm
ft
ft²

Pipe bores and watering target

in
in
in
%
Lateral pressure budget
psigUse pressure after the filter, regulator and mainline.
psig
ftPositive uphill. The max-run estimate holds the slope constant.

Results

Updates as you edit
Total zone flow9.6 gpm

The entered pressure budget and 5 ft/s velocity screen are met.

Pressure along the critical lateral
Pressure along the critical lateralFlow drops at each outlet. The pressure model keeps each outlet at its rated flow.08.416.825.233.64209.3518.728.0537.4Run distance (ft)Gauge pressure (psig)
  • Calculated pressure
  • Minimum outlet pressure

Flow drops at each outlet. The pressure model keeps each outlet at its rated flow.

Gross precipitation rate
0.49 in/h
Weekly run time
189.8 min
Mainline velocity
3.56 ft/s
Critical lateral inlet velocity
2.89 ft/s
Critical lateral inlet flow
4.8 gpm
Outlets on critical lateral
3
Lateral friction drop
0.44 psi
Lowest lateral pressure
33.56 psig

Worked calculation

  1. Count outlets and total the flow

    Zone flow = active heads × rated flow per head. Critical lateral uses the most-loaded branch.

    6 outlets give 9.6 gpm over 1,900 ft².

  2. Turn flow into application rate

    Gross depth per hour = hourly zone volume / wetted area

    The gross rate is 0.49 in/h and the net target is 1 in per week at 65 % efficiency.

  3. Calculate the weekly run time

    Minutes per week = 60 × target depth / (gross hourly rate × efficiency)

    The weekly runtime is 189.8 min.

  4. Track pressure down the lateral

    Each segment carries the flow for its remaining outlets. Segment head loss uses Hazen–Williams.

    Friction contributes 0.44 psi. Adding elevation gives a lowest gauge pressure of 33.56 psig.

What this example shows

Pressure available after the valve and filter controls the lateral. Compare the lowest modeled outlet pressure with the nozzle’s rated operating pressure.

Frequently asked questions

Can I mix spray heads with different flows in this six-head example?

Use equal flows for the model, or estimate with a representative value and check the highest-flow branch separately.

Why could the six sprays need multiple watering cycles in one session?

The gross application rate may exceed soil infiltration during a continuous run. Split the weekly total into intervals appropriate for the site.