Irrigation hydraulics

Flow and Weekly Run Time for Eight Rotor Sprinklers

Size an eight-rotor zone at 2.5 gpm per head across a 5,000 ft² lawn and two branches.

Inputs

Total zone flow20 gpm

Zone layout

gpm
ft
ft²

Pipe bores and watering target

in
in
in
%
Lateral pressure budget
psigUse pressure after the filter, regulator and mainline.
psig
ftPositive uphill. The max-run estimate holds the slope constant.

Results

Updates as you edit
Total zone flow20 gpm

The entered pressure budget and 5 ft/s velocity screen are met.

Pressure along the critical lateral
Pressure along the critical lateralFlow drops at each outlet. The pressure model keeps each outlet at its rated flow.020406080100012.3824.7537.1349.5Run distance (ft)Gauge pressure (psig)
  • Calculated pressure
  • Minimum outlet pressure

Flow drops at each outlet. The pressure model keeps each outlet at its rated flow.

Gross precipitation rate
0.39 in/h
Weekly run time
187 min
Mainline velocity
3.15 ft/s
Critical lateral inlet velocity
3.71 ft/s
Critical lateral inlet flow
10 gpm
Outlets on critical lateral
4
Lateral friction drop
1.15 psi
Lowest lateral pressure
43.85 psig

Worked calculation

  1. Count outlets and total the flow

    Zone flow = active heads × rated flow per head. Critical lateral uses the most-loaded branch.

    8 outlets give 20 gpm over 5,000 ft².

  2. Turn flow into application rate

    Gross depth per hour = hourly zone volume / wetted area

    The gross rate is 0.39 in/h and the net target is 0.9 in per week at 75 % efficiency.

  3. Calculate the weekly run time

    Minutes per week = 60 × target depth / (gross hourly rate × efficiency)

    The weekly runtime is 187 min.

  4. Track pressure down the lateral

    Each segment carries the flow for its remaining outlets. Segment head loss uses Hazen–Williams.

    Friction contributes 1.15 psi. Adding elevation gives a lowest gauge pressure of 43.85 psig.

What this example shows

The inlet to the whole zone sees 20 gpm. The critical branch sees four sprinklers. Use a catch-can test to refine the modeled application rate.

Frequently asked questions

Should overlapping rotor spray areas be added together?

Use the total ground area served by the zone once. Overlap is part of delivering uniform coverage over that same area.

How can I confirm the modeled rotor precipitation rate?

Run a catch-can test across the zone using the Irrigation Association methods or local extension instructions.