Irrigation hydraulics

Drip Tape Zone Flow with 0.25 GPH Emitters

Estimate flow and irrigation minutes for twelve 120 ft tape rows with 8-inch emitter spacing.

Inputs

Total zone flow9 gpm

Zone layout

ft
in
ft
gal/h

Pipe bores and watering target

in
in
in
%
Lateral pressure budget
psigUse pressure after the filter, regulator and mainline.
psig
ftPositive uphill. The max-run estimate holds the slope constant.

Results

Updates as you edit
Total zone flow9 gpm

The entered pressure budget and 5 ft/s velocity screen are met.

Pressure along the critical lateral
Pressure along the critical lateralFlow drops at each outlet. The pressure model keeps each outlet at its rated flow.02448729612002.474.957.429.9Run distance (ft)Gauge pressure (psig)
  • Calculated pressure
  • Minimum outlet pressure

Flow drops at each outlet. The pressure model keeps each outlet at its rated flow.

Gross precipitation rate
0.2 in/h
Weekly run time
282.6 min
Mainline velocity
1.93 ft/s
Critical lateral inlet velocity
0.78 ft/s
Critical lateral inlet flow
0.75 gpm
Outlets on critical lateral
180
Lateral friction drop
0.1 psi
Lowest lateral pressure
8.9 psig
Estimated maximum drip run
391.3 ft

Worked calculation

  1. Count outlets and total the flow

    Emitters per line = floor(run length / spacing). Zone flow = total emitters × flow per emitter.

    2,160 outlets give 9 gpm over 4,320 ft².

  2. Turn flow into application rate

    Gross depth per hour = hourly zone volume / wetted area

    The gross rate is 0.2 in/h and the net target is 0.85 in per week at 90 % efficiency.

  3. Calculate the weekly run time

    Minutes per week = 60 × target depth / (gross hourly rate × efficiency)

    The weekly runtime is 282.6 min.

  4. Track pressure down the lateral

    Each segment carries the flow for its remaining outlets. Segment head loss uses Hazen–Williams.

    Friction contributes 0.1 psi. Adding elevation gives a lowest gauge pressure of 8.9 psig. At the same slope, the pressure and velocity limits allow about 391.3 ft.

What this example shows

Zone flow depends on all twelve rows, while inlet flow for one lateral depends on that row’s outlets. Set the pressure budget to fit the tape’s regulated operating range.

Frequently asked questions

How many emitters are in one 120 ft tape row at 8-inch spacing?

There are 180 outlets in the model, with the first outlet one spacing from the inlet. Check the actual start offset on precut rows.

Why is the tape inlet set below common pressure-compensating dripline pressure?

Thin-wall tape can be designed for low pressure. Use the pressure range and regulation specified for the particular tape.