Drip Tape Zone Flow with 0.25 GPH Emitters
Estimate flow and irrigation minutes for twelve 120 ft tape rows with 8-inch emitter spacing.
Inputs
Results
Updates as you editThe entered pressure budget and 5 ft/s velocity screen are met.
- Calculated pressure
- Minimum outlet pressure
Flow drops at each outlet. The pressure model keeps each outlet at its rated flow.
- Gross precipitation rate
- 0.2 in/h
- Weekly run time
- 282.6 min
- Mainline velocity
- 1.93 ft/s
- Critical lateral inlet velocity
- 0.78 ft/s
- Critical lateral inlet flow
- 0.75 gpm
- Outlets on critical lateral
- 180
- Lateral friction drop
- 0.1 psi
- Lowest lateral pressure
- 8.9 psig
- Estimated maximum drip run
- 391.3 ft
Inputs
- Emitter type
- Inline drip
- Parallel drip laterals
- 12
- Drip lateral length
- 120 ft
- Emitter spacing
- 8 in
- Lateral row spacing
- 3 ft
- Flow per drip emitter
- 0.25 gal/h
- Mainline inside diameter
- 1.38 in
- Lateral inside diameter
- 0.625 in
- Net weekly water depth
- 0.85 in
- Application efficiency
- 90 %
- Pressure at lateral entrance
- 9 psig
- Minimum outlet pressure
- 6 psig
- Elevation change along run
- 0 ft
- Lateral Hazen–Williams C
- 150
Worked calculation
Count outlets and total the flow
Emitters per line = floor(run length / spacing). Zone flow = total emitters × flow per emitter.
2,160 outlets give 9 gpm over 4,320 ft².
Turn flow into application rate
Gross depth per hour = hourly zone volume / wetted area
The gross rate is 0.2 in/h and the net target is 0.85 in per week at 90 % efficiency.
Calculate the weekly run time
Minutes per week = 60 × target depth / (gross hourly rate × efficiency)
The weekly runtime is 282.6 min.
Track pressure down the lateral
Each segment carries the flow for its remaining outlets. Segment head loss uses Hazen–Williams.
Friction contributes 0.1 psi. Adding elevation gives a lowest gauge pressure of 8.9 psig. At the same slope, the pressure and velocity limits allow about 391.3 ft.
What this example shows
Zone flow depends on all twelve rows, while inlet flow for one lateral depends on that row’s outlets. Set the pressure budget to fit the tape’s regulated operating range.
Frequently asked questions
How many emitters are in one 120 ft tape row at 8-inch spacing?
There are 180 outlets in the model, with the first outlet one spacing from the inlet. Check the actual start offset on precut rows.
Why is the tape inlet set below common pressure-compensating dripline pressure?
Thin-wall tape can be designed for low pressure. Use the pressure range and regulation specified for the particular tape.