Irrigation hydraulics

Drip Lateral Pressure Drop on an Uphill Run

Assess a 210 ft drip lateral that rises 12 ft, with a 20 psi inlet and 12 psi minimum emitter pressure.

Inputs

Total zone flow7 gpm

Zone layout

ft
in
ft
gal/h

Pipe bores and watering target

in
in
in
%
Lateral pressure budget
psigUse pressure after the filter, regulator and mainline.
psig
ftPositive uphill. The max-run estimate holds the slope constant.

Results

Updates as you edit
Total zone flow7 gpm

The entered pressure budget and 5 ft/s velocity screen are met.

Pressure along the critical lateral
Pressure along the critical lateralFlow drops at each outlet. The pressure model keeps each outlet at its rated flow.0428412616821005.51116.522Run distance (ft)Gauge pressure (psig)
  • Calculated pressure
  • Minimum outlet pressure

Flow drops at each outlet. The pressure model keeps each outlet at its rated flow.

Gross precipitation rate
0.27 in/h
Weekly run time
250.8 min
Mainline velocity
2.6 ft/s
Critical lateral inlet velocity
2.45 ft/s
Critical lateral inlet flow
1.75 gpm
Outlets on critical lateral
140
Lateral friction drop
1.78 psi
Lowest lateral pressure
13.03 psig
Estimated maximum drip run
229.5 ft

Worked calculation

  1. Count outlets and total the flow

    Emitters per line = floor(run length / spacing). Zone flow = total emitters × flow per emitter.

    560 outlets give 7 gpm over 2,520 ft².

  2. Turn flow into application rate

    Gross depth per hour = hourly zone volume / wetted area

    The gross rate is 0.27 in/h and the net target is 0.95 in per week at 85 % efficiency.

  3. Calculate the weekly run time

    Minutes per week = 60 × target depth / (gross hourly rate × efficiency)

    The weekly runtime is 250.8 min.

  4. Track pressure down the lateral

    Each segment carries the flow for its remaining outlets. Segment head loss uses Hazen–Williams.

    Friction contributes 1.78 psi. Adding elevation gives a lowest gauge pressure of 13.03 psig. At the same slope, the pressure and velocity limits allow about 229.5 ft.

What this example shows

The uphill rise consumes part of the pressure budget before accounting for friction. Try shorter laterals at the same slope or compare a larger bore.

Frequently asked questions

How does a 12 ft uphill rise use pressure on the dripline?

It costs about 5.2 psi of water pressure head. The friction losses add to that elevation cost.

How do I compare a shorter run on the same uphill grade?

Scale the entered rise along with the length. The max-run result already holds the entered slope constant.