Off-grid pumping

Solar Pump Panel Derating in Hot, Dusty Conditions

Calculate array watts for a 1,200 gal/day well with 149°F PV cells and a 20% soiling loss.

Inputs

PV array nameplate power346 W

Water and sun

gal/day
ft
h/dayDaily solar energy expressed as equivalent full-sun hours.
h/dayUsed to size pump flow and instantaneous power.
%
daysDays of demand to compare for cistern and battery storage.
PV losses and well yield
°FCell temperature during operation.
%/°FPositive magnitude of the module data-sheet coefficient.
%
%
gpmEnter 0 if you do not have a yield test.
Battery assumptions
%
%
%
V

Results

Updates as you edit
PV array nameplate power346 W

Direct pumping uses the larger of the daily energy and instantaneous power estimates.

PV sizing limits
PV sizing limitsThe direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.Daily energy298.3 WDirect power346 WSelected array346 W

The direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.

Required pump flow
4 gpm
Pump electrical demand
213.9 W
Daily hydraulic energy
0.471 kWh/day
Daily pump electricity
1.07 kWh/day
PV output factor
61.8 %
Energy-limited array
298.3 W
Direct-pumping power floor
346 W
Cistern buffer equivalent
0 gal
Nominal battery equivalent
0 kWh
Battery capacity at bank voltage
0 Ah

Worked calculation

  1. Set the pump duty

    Q = daily volume / hours actually pumping

    1,200 gal/day in 5 h/day gives 4 gpm at 125 ft of TDH.

  2. Find the electrical energy at the pump

    Ewater = ρgVH. Epump = Ewater / wire-to-water efficiency.

    The water needs 0.471 kWh/day. At 44 % efficiency, the pump needs 1.07 kWh/day.

  3. Derate the PV modules

    PV factor = [1 − γ(Tcell − 25 °C)] × (1 − soiling) × (1 − other loss)

    The temperature factor is 84 % and the combined output factor is 61.8 %.

  4. Check daily energy and instantaneous power

    Wenergy = daily pump Wh / (peak sun hours × PV factor × storage efficiency)

    Daily energy gives 298.3 W. Direct pumping needs at least 346 W in the design-sun condition. The chosen mode yields 346 W.

  5. Allow for storage autonomy

    Cistern = daily volume × days. Nominal battery = pump kWh × days / (usable fraction × discharge efficiency).

    0 days gives 0 gal of cistern storage or 0 kWh of nominal battery capacity.

What this example shows

The cell-temperature, dust and wiring factors multiply. Alter soiling alone to estimate the effect of cleaning while keeping the hydraulic duty fixed.

Frequently asked questions

Which temperature matters for module derating in a hot field?

Use operating cell temperature. An illuminated module can run substantially warmer than ambient air.

Should I add 20% dust and the temperature loss directly?

Apply each fractional loss to the remaining output. The model multiplies the temperature, dust and wiring factors.