Solar Pump Panel Derating in Hot, Dusty Conditions
Calculate array watts for a 1,200 gal/day well with 149°F PV cells and a 20% soiling loss.
Inputs
Results
Updates as you editDirect pumping uses the larger of the daily energy and instantaneous power estimates.
The direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.
- Required pump flow
- 4 gpm
- Pump electrical demand
- 213.9 W
- Daily hydraulic energy
- 0.471 kWh/day
- Daily pump electricity
- 1.07 kWh/day
- PV output factor
- 61.8 %
- Energy-limited array
- 298.3 W
- Direct-pumping power floor
- 346 W
- Cistern buffer equivalent
- 0 gal
- Nominal battery equivalent
- 0 kWh
- Battery capacity at bank voltage
- 0 Ah
Inputs
- Daily water target
- 1,200 gal/day
- Total dynamic head
- 125 ft
- Peak sun hours
- 5.8 h/day
- Actual pumping window
- 5 h/day
- Wire-to-water efficiency
- 44 %
- Operating mode
- Direct to point of use
- Storage autonomy
- 0 days
- Design PV cell temperature
- 149 °F
- Power loss per degree
- 0.222 %/°F
- Soiling loss
- 20 %
- Wiring and mismatch loss
- 8 %
- Tested well yield
- 0 gpm
- Battery round-trip efficiency
- 85 %
- Discharge-path efficiency
- 92 %
- Usable depth of discharge
- 80 %
- Battery bank voltage
- 48 V
Worked calculation
Set the pump duty
Q = daily volume / hours actually pumping
1,200 gal/day in 5 h/day gives 4 gpm at 125 ft of TDH.
Find the electrical energy at the pump
Ewater = ρgVH. Epump = Ewater / wire-to-water efficiency.
The water needs 0.471 kWh/day. At 44 % efficiency, the pump needs 1.07 kWh/day.
Derate the PV modules
PV factor = [1 − γ(Tcell − 25 °C)] × (1 − soiling) × (1 − other loss)
The temperature factor is 84 % and the combined output factor is 61.8 %.
Check daily energy and instantaneous power
Wenergy = daily pump Wh / (peak sun hours × PV factor × storage efficiency)
Daily energy gives 298.3 W. Direct pumping needs at least 346 W in the design-sun condition. The chosen mode yields 346 W.
Allow for storage autonomy
Cistern = daily volume × days. Nominal battery = pump kWh × days / (usable fraction × discharge efficiency).
0 days gives 0 gal of cistern storage or 0 kWh of nominal battery capacity.
What this example shows
The cell-temperature, dust and wiring factors multiply. Alter soiling alone to estimate the effect of cleaning while keeping the hydraulic duty fixed.
Frequently asked questions
Which temperature matters for module derating in a hot field?
Use operating cell temperature. An illuminated module can run substantially warmer than ambient air.
Should I add 20% dust and the temperature loss directly?
Apply each fractional loss to the remaining output. The model multiplies the temperature, dust and wiring factors.