Off-Grid Cabin Solar Well for 500 Gallons per Day
Estimate pump flow and panel watts for a cabin using 500 gal/day at 95 ft of head with a small gravity storage tank.
Inputs
Results
Updates as you editDirect pumping uses the larger of the daily energy and instantaneous power estimates.
The direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.
- Required pump flow
- 2.08 gpm
- Pump electrical demand
- 95.5 W
- Daily hydraulic energy
- 0.149 kWh/day
- Daily pump electricity
- 0.382 kWh/day
- PV output factor
- 80.4 %
- Energy-limited array
- 105.6 W
- Direct-pumping power floor
- 118.8 W
- Cistern buffer equivalent
- 750 gal
- Nominal battery equivalent
- 0.78 kWh
- Battery capacity at bank voltage
- 16.2 Ah
Inputs
- Daily water target
- 500 gal/day
- Total dynamic head
- 95 ft
- Peak sun hours
- 4.5 h/day
- Actual pumping window
- 4 h/day
- Wire-to-water efficiency
- 39 %
- Operating mode
- Direct pump + cistern
- Storage autonomy
- 1.5 days
- Design PV cell temperature
- 113 °F
- Power loss per degree
- 0.222 %/°F
- Soiling loss
- 5 %
- Wiring and mismatch loss
- 8 %
- Tested well yield
- 3 gpm
- Battery round-trip efficiency
- 85 %
- Discharge-path efficiency
- 92 %
- Usable depth of discharge
- 80 %
- Battery bank voltage
- 48 V
Worked calculation
Set the pump duty
Q = daily volume / hours actually pumping
500 gal/day in 4 h/day gives 2.08 gpm at 95 ft of TDH.
Find the electrical energy at the pump
Ewater = ρgVH. Epump = Ewater / wire-to-water efficiency.
The water needs 0.149 kWh/day. At 39 % efficiency, the pump needs 0.382 kWh/day.
Derate the PV modules
PV factor = [1 − γ(Tcell − 25 °C)] × (1 − soiling) × (1 − other loss)
The temperature factor is 92 % and the combined output factor is 80.4 %.
Check daily energy and instantaneous power
Wenergy = daily pump Wh / (peak sun hours × PV factor × storage efficiency)
Daily energy gives 105.6 W. Direct pumping needs at least 118.8 W in the design-sun condition. The chosen mode yields 118.8 W.
Allow for storage autonomy
Cistern = daily volume × days. Nominal battery = pump kWh × days / (usable fraction × discharge efficiency).
1.5 days gives 750 gal of cistern storage or 0.78 kWh of nominal battery capacity.
What this example shows
The four-hour pump window sets a higher flow than the equivalent sun-hour number would suggest. This case sizes direct power and daily energy separately.
Frequently asked questions
Can I use the number of daylight hours for the cabin array input?
Use equivalent full-sun hours for the array. Enter a separate estimate of the hours during which the pump can actually operate.
What should I include in TDH to fill the cabin’s elevated tank?
Include the pumping water level, delivery elevation and friction at the planned flow. Add any residual pressure needed at the tank inlet.