Off-grid pumping

Winter Solar Well Pump with Three Days of Cistern Storage

Size a well pump for a 750 gal/day winter target with 2.8 peak sun hours and a three-day cistern buffer.

Inputs

PV array nameplate power283.1 W

Water and sun

gal/day
ft
h/dayDaily solar energy expressed as equivalent full-sun hours.
h/dayUsed to size pump flow and instantaneous power.
%
daysDays of demand to compare for cistern and battery storage.
PV losses and well yield
°FCell temperature during operation.
%/°FPositive magnitude of the module data-sheet coefficient.
%
%
gpmEnter 0 if you do not have a yield test.
Battery assumptions
%
%
%
V

Results

Updates as you edit
PV array nameplate power283.1 W

Direct pumping uses the larger of the daily energy and instantaneous power estimates.

PV sizing limits
PV sizing limitsThe direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.Daily energy283.1 WDirect power226.5 WSelected array283.1 W

The direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.

Required pump flow
3.57 gpm
Pump electrical demand
201.7 W
Daily hydraulic energy
0.282 kWh/day
Daily pump electricity
0.706 kWh/day
PV output factor
89 %
Energy-limited array
283.1 W
Direct-pumping power floor
226.5 W
Cistern buffer equivalent
2,250 gal
Nominal battery equivalent
2.88 kWh
Battery capacity at bank voltage
59.9 Ah

Worked calculation

  1. Set the pump duty

    Q = daily volume / hours actually pumping

    750 gal/day in 3.5 h/day gives 3.57 gpm at 120 ft of TDH.

  2. Find the electrical energy at the pump

    Ewater = ρgVH. Epump = Ewater / wire-to-water efficiency.

    The water needs 0.282 kWh/day. At 40 % efficiency, the pump needs 0.706 kWh/day.

  3. Derate the PV modules

    PV factor = [1 − γ(Tcell − 25 °C)] × (1 − soiling) × (1 − other loss)

    The temperature factor is 102 % and the combined output factor is 89 %.

  4. Check daily energy and instantaneous power

    Wenergy = daily pump Wh / (peak sun hours × PV factor × storage efficiency)

    Daily energy gives 283.1 W. Direct pumping needs at least 226.5 W in the design-sun condition. The chosen mode yields 283.1 W.

  5. Allow for storage autonomy

    Cistern = daily volume × days. Nominal battery = pump kWh × days / (usable fraction × discharge efficiency).

    3 days gives 2,250 gal of cistern storage or 2.88 kWh of nominal battery capacity.

What this example shows

Colder modules improve the temperature factor in this case, while shorter winter sun hours raise the calculated nameplate requirement. Use a winter design-month irradiance value.

Frequently asked questions

Can a three-day cistern compensate for a winter energy deficit every day?

Storage shifts water across days. Long-term production still needs to cover water use through the design period.

Why can the winter PV temperature factor exceed 100%?

A module can deliver more than its 25°C reference rating at the same irradiance when the cells are colder. Other losses still apply.