Winter Solar Well Pump with Three Days of Cistern Storage
Size a well pump for a 750 gal/day winter target with 2.8 peak sun hours and a three-day cistern buffer.
Inputs
Results
Updates as you editDirect pumping uses the larger of the daily energy and instantaneous power estimates.
The direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.
- Required pump flow
- 3.57 gpm
- Pump electrical demand
- 201.7 W
- Daily hydraulic energy
- 0.282 kWh/day
- Daily pump electricity
- 0.706 kWh/day
- PV output factor
- 89 %
- Energy-limited array
- 283.1 W
- Direct-pumping power floor
- 226.5 W
- Cistern buffer equivalent
- 2,250 gal
- Nominal battery equivalent
- 2.88 kWh
- Battery capacity at bank voltage
- 59.9 Ah
Inputs
- Daily water target
- 750 gal/day
- Total dynamic head
- 120 ft
- Peak sun hours
- 2.8 h/day
- Actual pumping window
- 3.5 h/day
- Wire-to-water efficiency
- 40 %
- Operating mode
- Direct pump + cistern
- Storage autonomy
- 3 days
- Design PV cell temperature
- 68 °F
- Power loss per degree
- 0.222 %/°F
- Soiling loss
- 3 %
- Wiring and mismatch loss
- 10 %
- Tested well yield
- 0 gpm
- Battery round-trip efficiency
- 85 %
- Discharge-path efficiency
- 92 %
- Usable depth of discharge
- 80 %
- Battery bank voltage
- 48 V
Worked calculation
Set the pump duty
Q = daily volume / hours actually pumping
750 gal/day in 3.5 h/day gives 3.57 gpm at 120 ft of TDH.
Find the electrical energy at the pump
Ewater = ρgVH. Epump = Ewater / wire-to-water efficiency.
The water needs 0.282 kWh/day. At 40 % efficiency, the pump needs 0.706 kWh/day.
Derate the PV modules
PV factor = [1 − γ(Tcell − 25 °C)] × (1 − soiling) × (1 − other loss)
The temperature factor is 102 % and the combined output factor is 89 %.
Check daily energy and instantaneous power
Wenergy = daily pump Wh / (peak sun hours × PV factor × storage efficiency)
Daily energy gives 283.1 W. Direct pumping needs at least 226.5 W in the design-sun condition. The chosen mode yields 283.1 W.
Allow for storage autonomy
Cistern = daily volume × days. Nominal battery = pump kWh × days / (usable fraction × discharge efficiency).
3 days gives 2,250 gal of cistern storage or 2.88 kWh of nominal battery capacity.
What this example shows
Colder modules improve the temperature factor in this case, while shorter winter sun hours raise the calculated nameplate requirement. Use a winter design-month irradiance value.
Frequently asked questions
Can a three-day cistern compensate for a winter energy deficit every day?
Storage shifts water across days. Long-term production still needs to cover water use through the design period.
Why can the winter PV temperature factor exceed 100%?
A module can deliver more than its 25°C reference rating at the same irradiance when the cells are colder. Other losses still apply.